Schneider Electric XPS AF 24 V ac/dc Safety Relay Single or Dual Channel With 3 Safety Contacts - Preventa Range

Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): ID
Product Details

Schneider Electric | Preventa XPSAF Series | Safety Relays

Simple and effective safety monitoring has never been more crucial in today's highly automated world. Prevention is key to site safety, that's why Schneider Electric offers a Safety Relay in the form of the 'Preventa XPSAF' module that is second to none. Being able to monitor faults with devices along a circuit has the power to stop emergency situations from even occurring.

Features and benefits:

• Single-channel with 3 N/O safety outputs

• Monitoring of a movable guard, with emergency stop monitoring 1 or 2 channel wiring usable.

• Configurable type of start is readily available for the type of activation you wish for your circuit.

• Monitoring of single safety functions, providing an automated solution for use with applications such as emergency push stop buttons or switches.

• Unlimited synchronisation between time inputs.

• Slin in design, with just 22.5mm of width meaning it can fit nicely even in space constraint spaces.

• Accepts cable up to 2.5mm²

• Symmetrical DIN rail support, offering flexible and versatile safety system installation.

• Local signalling in the form of LEDs.

Protection ratings & Safety features (see datasheet for specifics) -

• Impressive line resistance is available, varying between 90 to 100 Ohm (Ω).

• Input protection type is internal, electronic.

• EN1088/ISO 14119, EN 60204-1, EN/IEC 60947-5-1, EN/ISO 13850

• CSA, TUV & UL listed

• IP 40 (enclosure) for protection against small objects up to 1mm such as tools, wires and small wires.

• IP 20 (terminals) for protection against solid objects such as fingers, smaller tools up to 12mm.

• -25 to 60°C temperature range for operation, suitable in varying levels of heat/freezing temperatures.

Applications -

All dangerous machinery requires an automated solution to prevent harm to immediate users and also prevent damage to the machinery. Below are some of the safety applications

• Coded Magnetic Switch (CMS) to prevent tampering by unauthorised users.


• Time delay input if needed allowing you to set up your own time function.

• Light curtains / Two-hand control safety circuits

• Sensing mats and edges

Standards

IEC 204-1; EN 292; EN 418; EN 60204-1; EN 1088

Approvals

BG, UL, CSA

Specifications
Attribute Value
Supply Voltage 24 V ac/dc
Number of Channels 1, 2
Function Safety Switch/Interlock
Safety Contacts 3
Range Preventa
Terminal Type Screw
Width 22.5mm
Length 99mm
Depth 114mm
61 In stock - FREE next working day delivery available
Price Each
£ 149.00
(exc. VAT)
£ 178.80
(inc. VAT)
Units
Per unit
1 +
£149.00
Related Products
The Omron G9SB series is an ultra slim ...
Description:
The Omron G9SB series is an ultra slim safety relay available in either a 17.5mm or 22.5mm housing. The 17.5mm units have 2 or 3 safety contacts and the 22.5mm units have 3 safety contacts and an auxiliary contact. 1 and 2 input channel units Manual and automatic reset units ...
Line fault detection on On-button:Manual restart or automatic ...
Description:
Line fault detection on On-button:Manual restart or automatic restart With or without cross fault monitoring2-channel Forcibly guided output contacts Output: max. 4 NO instantaneous semiconductor monitoring output LED indicator for operation, delay contacts and failure As option with pluggable terminal blocks for easy exchange of deviceswith screw terminalsor with cage ...
The BG5924 is a highly compact safety switch ...
Description:
The BG5924 is a highly compact safety switch device for the construction of emergency stop switches. It serves to protect personnel and machines in accordance with the EC directive for machines 89/392/EEC, IEC 204-1, EN 60204-1, DIN VDE 0113-1. Single-channel circuit Safety category conforms to EN 954 internal: 4 external: ...
Safety category 4 in accordance with DIN EN ...
Description:
Safety category 4 in accordance with DIN EN 954Output: 2 N/Os, 1 N/C1 or 2-channel configuration Line termination detection on the ON button Programmable: Activation via the ON button or automatic ON function when the operating voltage is applied Programmable: With / without cross-fault detection in the emergency stop-control loop ...