Dold BN 5983 230 V ac Safety Relay Dual Channel With 3 Safety Contacts - Safemaster Range and 1 Auxiliary Contact

  • RS Stock No. 240-8686
  • Mfr. Part No. BN5983.53 AC50/60Hz 230V
  • Brand Dold
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Emergency Stop Module, BN5983.53

Machine emergency stop switches
Monitors safety doors
SK 3 (with equivalent switching)
Output: 3 N/Os, 1 N/C for AC 380 V
1 or 2-channel configuration
LED indicators for channels 1 and 2
Control loop X3-X4 for monitoring external protection
Removable terminals

Protection of humans and machines in accordance with: EC Directive on Machines 89/392/EEC, IEC 204, EN 60204, DIN VDE 0113

Standards

EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1

Approvals

BG, TÜV-Rheinland, UL, CSA, SUVA, SA Sweden,
Arbejdstilsynet Denmark

//media.rs-online.com/t_line/LD240868-01.gif
Specifications
Attribute Value
Supply Voltage 230 V ac
Number of Channels 2
Auxiliary Contacts 1
Function Emergency Stop
Safety Contacts 3
Range Safemaster
Reset Method Monitored
Terminal Type Terminal Block
Depth 121mm
Width 100mm
Length 74mm
3 In stock for delivery within 1 working days
Price Each
£ 307.94
(exc. VAT)
£ 369.53
(inc. VAT)
Units
Per unit
1 +
£307.94
Not available for guaranteed pre 9am/10am delivery
Related Products
Stop-Category 0 acc. EN 60204-1Applications up to Category ...
Description:
Stop-Category 0 acc. EN 60204-1Applications up to Category 4 acc. EN 954-1, to SIL 3 according to EN62061 and PL e according to EN13849-1Can be used as emergency stop and safety gate monitor Manual reset with self-monitoring on each ON-OFF cycle Cross monitoring One or two-channel wiring External device monitoring ...
The Bernstein AG 3NO 24VDC SCR relay is ...
Description:
The Bernstein AG 3NO 24VDC SCR relay is housed in a slim-line DIN rail polyamide material housing. The SCR relay is used to monitor the correct position and reliable operation of inputs from the safety sensors or safety switch contacts. • Compact in dimension 22.5mmx114.5mmx99mm • Feedback loop with monitored/automatic ...
The Schneider Electric safety module has application for ...
Description:
The Schneider Electric safety module has application for electrical monitoring of two-hand control stations, safety switchover contact, emergency stop, guard and light curtain monitoring and monitoring antivalent contacts. Minimum output current : 10 mA for relay output Minimum output voltage : 15 V for relay output Ambient air temperature for ...
Machine emergency stop switches Monitoring sliding grill guards ...
Description:
Machine emergency stop switches Monitoring sliding grill guards SK 4 (with equivalent switching)Ultra compact unit (width 45 mm)Output: 3 N/Os, 1 N/C1 or 2-channel configuration Line termination detection on the ON button Programmable: cross-fault detection in emergency stop-control loop Programmable: automatically comes on when operational voltage is applied or activation ...