Omron G9SX, 24V dc Safety Relay, 2 Safety Contacts, 2
- RS Stock No.:
- 214-6821
- Mfr. Part No.:
- G9SX-BC202-RC DC24
- Brand:
- Omron
Subtotal (1 unit)*
£286.13
(exc. VAT)
£343.36
(inc. VAT)
FREE delivery for orders over £60.00
In Stock
- 1 unit(s) ready to ship
- Plus 3 unit(s) shipping from 19 October 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | £286.13 |
*price indicative
- RS Stock No.:
- 214-6821
- Mfr. Part No.:
- G9SX-BC202-RC DC24
- Brand:
- Omron
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Omron | |
| Product Type | Safety Relay | |
| Safety Contacts | 2 | |
| Contact Configuration | 3PST | |
| Number of Auxiliary Contacts | 2 | |
| Reset Method | Manual | |
| Mount Type | DIN Rail | |
| Power Consumption | 3W | |
| Series | G9SX | |
| Terminal Type | Spring Cage | |
| Time Delay | 50 ms | |
| Switching DC Voltage | 24V dc | |
| Standards/Approvals | EN, UR, CSA | |
| Switching AC Voltage | 24V | |
| Contact Current | 0.8A | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 55°C | |
| Length | 115mm | |
| Width | 23mm | |
| Height | 100mm | |
| Safety Category | 4 | |
| Hazardous Area Certification | No | |
| Coil Voltage | 24V dc | |
| Select all | ||
|---|---|---|
Brand Omron | ||
Product Type Safety Relay | ||
Safety Contacts 2 | ||
Contact Configuration 3PST | ||
Number of Auxiliary Contacts 2 | ||
Reset Method Manual | ||
Mount Type DIN Rail | ||
Power Consumption 3W | ||
Series G9SX | ||
Terminal Type Spring Cage | ||
Time Delay 50 ms | ||
Switching DC Voltage 24V dc | ||
Standards/Approvals EN, UR, CSA | ||
Switching AC Voltage 24V | ||
Contact Current 0.8A | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 55°C | ||
Length 115mm | ||
Width 23mm | ||
Height 100mm | ||
Safety Category 4 | ||
Hazardous Area Certification No | ||
Coil Voltage 24V dc | ||
Omron G9SX Series Safety Relay, 24V DC Coil Voltage, 0.8A Contact Current - G9SX-BC202-RC DC24
This safety relay provides monitored safety switching for machinery control within industrial automation systems. Designed for DIN-rail mounting and 24V DC supply, it offers low-current solid-state outputs alongside relay expansion options for controlled stop functions and logical AND I/O expansion. The unit supports manual reset and can be integrated with feedback loops, logical AND networks and expansion modules to segment hazards or coordinate emergency-stop and guard inputs in complex systems.
Features & Benefits
• 24V DC Coil minimises supply complexity and integration effort
• 0.8A DC output current allows driving small solid-state loads
• 50ms operating time supports timely hazard response
• Spring-cage terminals reduce wiring time and improve contact reliability
• Two safety contacts Plus two auxiliary contacts enable monitored control
• Safety Category 4 compliance meets high-integrity system requirements
• 0.8A DC output current allows driving small solid-state loads
• 50ms operating time supports timely hazard response
• Spring-cage terminals reduce wiring time and improve contact reliability
• Two safety contacts Plus two auxiliary contacts enable monitored control
• Safety Category 4 compliance meets high-integrity system requirements
**Applications**
• Suitable for emergency-stop circuits in production lines
• Ideal for guarding doors on parts-processing machines
• Used with safety light curtains for access control
• Can be used for segmented machine-stop logic via logical AND
• Suitable for expansion with relay output modules for larger systems
• Ideal for guarding doors on parts-processing machines
• Used with safety light curtains for access control
• Can be used for segmented machine-stop logic via logical AND
• Suitable for expansion with relay output modules for larger systems
What environmental range can be expected for site installation?
The device operates between −25°C to 55°C and requires no condensation or icing during use.
How is the reset function implemented on site?
A manual reset mode is provided via the feedback/reset input
auto-reset can be selected by wiring the corresponding terminal.
What Terminal and mounting conveniences aid fast commissioning?
Spring-cage terminals are fitted for secure, tool-free conductor retention and the module clips to a standard DIN rail.
How does the unit handle OFF-delay outputs?
OFF-delay outputs can be set via preset switches with selectable delay steps
setting to 0 s converts them to instantaneous outputs.