Phoenix Contact PSR-MC32 24 → 230 V ac/dc Safety Relay Dual Channel With 3 Safety Contacts

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

PSR-MC32-3NO-1NC-24-230UC-SP

The Phoenix Contact 2700525 safety relay is designed for emergency stop (E-Stop), light grids and safety doors up to Cat.4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061
With 3 enabling current path and 1 signalling current path the PBT safety relay has a cage-clamp connection and can be DIN rail mounted.

Features and Benefits

• Width of 22.5mm
• 1 or 2 channel operation
• Cross circuit detection
• A single device for manually monitoring and automatic activation
• LED display

Standards

DIN EN 50178, EN 60947-5-1

Specifications
Attribute Value
Supply Voltage 24 → 230 V ac/dc
Number of Channels 2
Function Emergency Stop
Safety Contacts 3
Reset Method Manual
Safety Category 2
Terminal Type Terminal Block
Width 22.5mm
Length 117.4mm
Depth 114.5mm
1 in stock for FREE next working day delivery
1 available from Europe for delivery within 1 working day(s)
Price Each
£ 263.21
(exc. VAT)
£ 315.85
(inc. VAT)
Units
Per unit
1 +
£263.21
Related Products
SIRIUS safety relay Basic unit 3SK2 series 10 ...
Description:
SIRIUS safety relay Basic unit 3SK2 series 10 F-DI, 2 F-DQ, 1 DQ, 24 V DC Can be parameterized via SIRIUS Safety ES 22.5 mm overall width Spring-type terminal (push-in). Output expansions 3SK1 and fail-safe motor starters 3RM1 via device connector connect able.
Coupling relay for SIL 3 high and low-demand ...
Description:
Coupling relay for SIL 3 high and low-demand applications, couples digital output signals to the I/O, 1 enabling current path, 1 confirmation current path, safe state off applications, test pulse filter, fixed screw terminal block. Possible signal generators Failsafe controllers Contact type1 undelayed enabling current path1 undelayed confirmation current path ...
The PSR safety relays from Phoenix contacts can ...
Description:
The PSR safety relays from Phoenix contacts can be quickly and reliably assembled to form a tailor-made safety solution. To connect using TBUS correctly you will need one PSR-TBUS per module. For the last additional module use one PSR-TBUS-TP instead, this will close the feedback loop. The interface module is ...
The PSR classic safety relays for single or ...
Description:
The PSR classic safety relays for single or two-channel emergency stop (E-Stop) and safety door monitoring from Phoenix Contact can be connected easily without the need for additional settings on the relay. They are an excellent solution when your system or machine only requires a few reliable safety functions. • ...