SSR10 is a safety relay with relay outputs, 3 NO + 1 NC, and a +24 VDC supply voltage.SSR10 is used with safety devices with contacts, 1 or 2 channels , and safety devices with OSSD outputs. The reset function, automatic or manual, is set with a switch on the front.

Specifications
Attribute Value
Supply Voltage 24 V dc
Number of Channels 3
Auxiliary Contacts 3NO/NC
Function Safety Switch
Safety Contacts 4
Range Sentry
Reset Method Multi-Reset
Safety Category 4
Terminal Type Screw
Width 120mm
Depth 120mm
Length 22.5mm
8 In stock for FREE next working day delivery
Price Each
£ 116.66
(exc. VAT)
£ 139.99
(inc. VAT)
Units
Per unit
1 +
£116.66
Related Products
The JSHD series from ABB Jokab offers the ...
Description:
The JSHD series from ABB Jokab offers the ability to operate machinery safely via a three position control device. Many different versions are available for a wide variety of applicational uses. Key features which have been incorporated within this series from ABB Jokab include a front button (for programme start, ...
Professional range of IDEM VIPER Safety Relays with ...
Description:
Professional range of IDEM VIPER Safety Relays with pluggable terminals. The safety relays incorporate expansion units. The relays can be directly wired to increase the number of safety output contacts. Designed to meet the latest safety standard and offer enhanced LED diagnostics and simplified wiring. Typical applications include safety interlock ...
TSR10 is a safety relay/safety timer with delayable ...
Description:
TSR10 is a safety relay/safety timer with delayable relay outputs, 3 NO+ 1 NC, and a +24 VDC power supply.TSR10 offers 0-999 seconds timer functions with a better accuracy than 1%: OFF-delay, ON-delay, Time bypass and Time reset.A display on its front facilitate configuration and troubleshooting by displaying error codes ...
Line fault detection on On-button:Manual restart or automatic ...
Description:
Line fault detection on On-button:Manual restart or automatic restart With or without cross fault monitoring2-channel Forcibly guided output contacts Output: 2 NO contacts per safety function1 semiconductor output per safety function LED indicator for operation, safety function 1, 2 and failure As option with pluggable terminal blocks for easy exchange ...