Schneider Electric XPS ATE 230 V ac Safety Relay Dual Channel With 2 Safety Contacts

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): ID
Product Details

XPS ATE, Dual Channel with Timed Delay (0-30s)

2 N/O instantaneous outputs provide stop category 0, 3 N/O timed contacts provide stop category 1 by allowing controlled deceleration of the motor until a complete stop is achieved
4 solid state outputs for PLC signalling
Monitored start button feature
Delay time: 0 – 30 s. adjustable in 12 steps by using the selector switch in the module front cover
Provides protection for machine and operator by immediately stopping dangerous movement on receipt of a stop instruction from operator, or on detection of a fault in the safety circuit. Applications include safety mats, safety edges, e-stop and safety gates
2 channel monitoring and feedback loop
Shorts across contacts, between channels and ground monitored
Voltage on input channels: 48Vdc
4 LEDs to indicate control supply/fuse, input channel A and B, stop Cat. 1 outputs closed
Internal electronic fuse for input channels reset on removal of fault
Synchronisation time between input A and B when using automatic start feature = 75ms approx
Pull off terminals for a simple and quick maintenance

Specifications
Attribute Value
Supply Voltage 230 V ac
Number of Channels 2
Auxiliary Contacts 4
Function Emergency Stop, Safety Mat/Edge, Safety Switch/Interlock
Safety Contacts 2
Range Preventa
Reset Method Automatic, Manual
Terminal Type Screw
Depth 114mm
Length 99mm
Width 45mm
5 In stock for FREE next working day delivery
Price Each
£ 370.00
(exc. VAT)
£ 444.00
(inc. VAT)
Units
Per unit
1 +
£370.00
Related Products
Stop-Category 0 acc. EN 60204-1Applications up to Category ...
Description:
Stop-Category 0 acc. EN 60204-1Applications up to Category 4 acc. EN 954-1, to SIL 3 according to EN62061 and PL e according to EN13849-1Can be used as emergency stop and safety gate monitor Manual reset with self-monitoring on each ON-OFF cycle Cross monitoring One or two-channel wiring External device monitoring ...
Stop-Category 0 acc. EN 60204-1Applications up to Category ...
Description:
Stop-Category 0 acc. EN 60204-1Applications up to Category 4 acc. EN 954-1, to SIL 3 according to EN62061 and PL e according to EN13849-1Can be used as emergency stop and safety gate monitor Manual reset with self-monitoring on each ON-OFF cycle Cross monitoring One or two-channel wiring External device monitoring ...
Machine emergency stop switches Monitoring sliding grill guards ...
Description:
Machine emergency stop switches Monitoring sliding grill guards SK 4 (with equivalent switching)Ultra compact unit (width 45 mm)Output: 3 N/Os, 1 N/C1 or 2-channel configuration Line termination detection on the ON button Programmable: cross-fault detection in emergency stop-control loop Programmable: automatically comes on when operational voltage is applied or activation ...
Protection of humans and machines in accordance with: ...
Description:
Protection of humans and machines in accordance with: EC Directive on Machines 89/392/EEC, IEC 204, EN 60204, DIN VDE 0113. Machine emergency stop switches Monitoring sliding grill guards SK 4 (with equivalent switching)Output: 2 N/Os for AC 250 V1 or 2-channel configuration Line termination detection on the ON button Optional: ...