XCSA Safety Interlock Switch

3 positive opening contacts as standard (on guard opening)
A key operated lock enables positive locking of the guard
Optional version with orange LED to indicate guard open/closed
Heavy duty metal DIN style
Turret heads can be rotated through 360° in 90 steps
8 actuator entries and 1 tapped entry
20N minimum operating force for positive opening
IP67 rating
Productivity is increased due to the third contact dedicated to diagnostics
Preventa XCS Safety Switches

Note

Actuators must be purchased separately, see accessories table

Standards

Conforms to EN1088, EN60204

Interlock Switch

Specifications
Attribute Value
Connection Type 1/2 in NPT
Lock Style Key
Normal State Configuration 3NC
Housing Material Zamak
Maximum AC Voltage 240V
Maximum DC Voltage 250V
Safety Contacts 3NC
Range Preventa
Actuator Included Yes
Number of Head Directions 8
Series XCSA
Length 40mm
Width 44mm
Depth 114mm
Minimum Operating Temperature -25°C
Dimensions 40 x 44 x 114 mm
IP Rating IP67
Standards Met CSA, CSA C22.2 No. 14, EN 1088, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/ISO 12100, ISO 14119, TC, UL, UL 508
Maximum Operating Temperature +70°C
Maximum Current 6 A
2 In stock for FREE next working day delivery
Price Each
£ 73.00
(exc. VAT)
£ 87.60
(inc. VAT)
Units
Per unit
1 +
£73.00
Related Products
1. Operation of pedal up to pressure point:the ...
Description:
1. Operation of pedal up to pressure point:the work contact is closed and the work process is initiated.2. In an emergency situation, operate beyond the pressure point resistor:The work contact is stopped and locked and the work process is stopped. Furthermore, when the pedal is not in operation, interlocking stays ...
Suitable for interlocking small moveable guards (EN1088, EN60204, ...
Description:
Suitable for interlocking small moveable guards (EN1088, EN60204, EN292)2 positive opening contacts as standard, on guard opening1 N/C positive internal control contact operated by the solenoid Key operated lock to allow authorised override of solenoid Solenoid continuously rated 10VA, voltage limits -20 / +10% (including ripple on d.c.)Turret heads can ...
Our Rotary Trapped Key Interlock Switches are used ...
Description:
Our Rotary Trapped Key Interlock Switches are used for electrical isolation of machinery to improve safe access and also as teach boxes in robot cells. Once the power has been turned off, the key can be withdrawn and used in the next sequence of operation such as unlocking an access ...
Lightweight yet robust: Hybrid of metal and plastic ...
Description:
Lightweight yet robust: Hybrid of metal and plastic Flexible contact assembly Integrated manual release Symmetrical design Five actuating positions Rotatable head (4´90°)Fail-safe guard locking system Optional emergency exit Optional emergency releaseM12 connector as an option Enclosure: Thermoplastic, glass fibre reinforced Cover: Thermoplastic, glass fibre reinforced Operating device: Metal Latching force: ...