Eaton 1+N Pole Type B Residual Current Circuit Breaker with Overload Protection, 32A Concept, 10 kA

  • RS Stock No. 341-4452
  • Mfr. Part No. 235986 & PKNM-32/1N/B/003-PT-DW
  • Brand Eaton
Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
Product Details

RCBOs

Manufactured to BS EN 61009
Flying lead neutral cable for easy installation
Type B MCB and 30mA RCD combined in one device
10kA MCB/RCBO breaking capacity
Type B MCB/RCBO operating characteristic

F&G Concept 2000 Incoming & Outgoing Devices

For use as spares and replacements in F&G Concept 2000 consumer units

Specifications
Attribute Value
Current Rating 32A
Series Concept
Tripping Characteristics Type B
Number of Poles 1+N
Breaking Capacity at Maximum Voltage Rating 10 kA
2 In stock - FREE next working day delivery available
Price Each
£ 128.50
(exc. VAT)
£ 154.20
(inc. VAT)
Units
Per unit
1 - 9
£128.50
10 - 14
£120.81
15 +
£115.67
Related Products
ID'clic differential plug-in switches, protected against inadvertent tripping. ...
Description:
ID'clic differential plug-in switches, protected against inadvertent tripping. Used only with Distri'clic XE splitters;Used for protection of "blue tariff" installations. Supply voltage 230 Vac.Standard AC graphs, A for detecting default current with continuous components or Asi for improved immunity. ID'clic XE 30 mA two-pole differential switches.
From Siemens the 5SV3 series are RCCBs suitable ...
Description:
From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highly reliable performance and excellent quality. Residual current operated circuit breaker for personnel and fire protection Silicone free2 or 4 ...
The Schneider Electric 100A residual current breaker with ...
Description:
The Schneider Electric 100A residual current breaker with overcurrent protection has a 60Hz of network frequency it has instantaneous protection time delay of earth leakage and It used 2P poles. Its net weight is 195g and it used toggle for control and it is in grey colour. Earth-leakage sensitivity is ...
The Eaton Residual current circuit breaker PXF, 4-pole, ...
Description:
The Eaton Residual current circuit breaker PXF, 4-pole, rated current In: 63 A, rated short-circuit strength Icn: 10 kA, rated residual current I?N: 0.3 A, switchgear for residential and commercial buildings. AC / DC sensitive IP40, IP54 (with moisture-proof housing)Surge current proof 3 k AIEC / EN 61008 and IEC ...