Eaton 4P 40 A Instantaneous RCD, Trip Sensitivity 30mA

  • RS Stock No. 922-8664
  • Mfr. Part No. PFIM-40/4/003-A-MW
  • Brand Eaton
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): RO
Product Details

PFIM Series

Professional range of Eaton compact residual current devices from the PFIM series. Each device incorporates a real contact position indictor. Ideal for fault current/residual current protection and extra protection in a wide range of application. Various tripping current ratings are available.

Eaton RCCBs

Specifications
Attribute Value
Number of Poles 4
Current Rating 40 A
Trip Sensitivity 30mA
Rated AC Voltage 230 400 V
Mounting Style DIN Rail
Range PFIM
Break Time Instantaneous
Series PFIM
Overall Depth 80mm
Special Features Automatic Reset, Contact Position Indicator
Terminal Contact Type Screw
Tripping Characteristics Type A
Overall Length 70mm
Reset Actuator Type Toggle Switch
Overall Width 65.5mm
Overall Dimensions 70 x 65.5 x 80mm
Circuit Breaker Type RCCB
1 In stock for FREE next working day delivery
Price Each
£ 110.64
(exc. VAT)
£ 132.77
(inc. VAT)
Units
Per unit
1 +
£110.64
Related Products
Time-delayed SMISSLINE RCCBWith integrated input wiring Contact position ...
Description:
Time-delayed SMISSLINE RCCBWith integrated input wiring Contact position display Upper input terminals can be used as feed Pluggable in any position Sensitive to AC and pulsed DC fault currents Double-level output terminal.
SMISSLINE FI circuit breaker Free selection and display ...
Description:
SMISSLINE FI circuit breaker Free selection and display of the contacting phase Sensitive to AC and pulsed DC fault currents With integrated input wiring Contact position display Upper input terminals can be used as feed Pluggable in any position Double-level output terminal.
From Siemens the 5SV3 series are RCCBs suitable ...
Description:
From Siemens the 5SV3 series are RCCBs suitable for personnel and fire protection. Available in 2 or 4 pole versions, each breaker can be DIN rail mounted. 5SV3 RCCBs offer highly reliable performance and excellent quality. Residual current operated circuit breaker for personnel and fire protection Silicone free2 or 4 ...
Digital residual current circuit-breaker, 40A, 4p, 30mA, type ...
Description:
Digital residual current circuit-breaker, 40A, 4p, 30mA, type G/B. All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents Integrated auxiliary contact Local Indication through 3 LEDs4-pole types can also be used as 2-pole devices ...