Allen Bradley 1492-RCDA 4P 25 A RCD Switch, Trip Sensitivity 100mA, DIN Rail Mount Mounted

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): IT
Product Details

1492 Series

Allen Bradley general purpose RCDs from the 1492 series. The RCDs have a Type A tripping characteristic and an instantaneous break time. 2 or 4 pole versions available. All the RCDs incorporate screw terminals and can be DIN Rail mounted.

Features & Benefits

2 or 4 pole versions
DIN Rail mount
Screw Terminals

Allen Bradley RCBs

Specifications
Attribute Value
Number of Poles 4
Current Rating 25 A
Trip Sensitivity 100mA
Rated AC Voltage 230 V, 400 V
Mounting Style DIN Rail Mount
Series 1492-RCDA
Terminal Contact Type Screw
Overall Depth 75mm
Breaking Capacity 1 (Residual) kA, 10 (Short-Circuit) kA
Overall Width 88mm
Circuit Breaker Type RCD
Application Industrial
Overall Dimensions 70 x 88 x 75mm
Reset Actuator Type Toggle Switch
Overall Length 70mm
Available to back order for despatch 28/10/2019
Price Each
£ 96.24
(exc. VAT)
£ 115.49
(inc. VAT)
Units
Per unit
1 +
£96.24
Related Products
The Silicon Labs broad range of Digital Isolation ...
Description:
The Silicon Labs broad range of Digital Isolation products offers significant improvements over older isolation technologies such as opto-couplers. They demonstrate lower power consumption, greater reliability and higher performance, and are generally smaller in size and lower in cost. These CMOS-based devices exhibit stable operating characteristics over a wide temperature ...
Fault current circuit breaker, conditionally current-proof up to ...
Description:
Fault current circuit breaker, conditionally current-proof up to 250 APulsed current sensitive, type AContour and bus bar compatible with other P-Series devicesDouble terminal with lift / jaw top and bottomFree selection of rail arrangement top and bottomFree terminal space despite bus bar mountingProtects from special non-smoothened forms of DC fault ...
Fault current circuit breaker, conditionally current-proof up to ...
Description:
Fault current circuit breaker, conditionally current-proof up to 250 APulsed current sensitive, type AContour and bus bar compatible with other P-Series devicesDouble terminal with lift / jaw top and bottomFree selection of rail arrangement top and bottomFree terminal space despite bus bar mountingProtects from special non-smoothened forms of DC fault ...
With integrated mounting rail for right-aligned mounting of ...
Description:
With integrated mounting rail for right-aligned mounting of 2, 3 and 4-pin automatic cut-outs in S200 seriesNeutral conductor connector can be mounted to right or leftApplications: escalators, lifts, electrically-operated gates and barriers, machine tools, car washes, assembly lines and conveyor belts.