Powerbreaker Inline Mains RCD Connector Adapter Corded 2 Pole ,Rated At 10A,230 V ac

Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): US
Product Details

In-Line RCD Adaptor

An In-Line IEC lead with RCD for the protection of personnel using permanent or semi-permanent equipment on many commercial and industrial applications.

Suitable for BS/European power supply systems
Robust construction
Double pole breaking
Mechanical flag to indicate contact position
Separate test and reset buttons
Rated current 10A / 2400W
Lead length O/P 0.3m

Standards

IEC 60320; BS7071

Specifications
Attribute Value
Type Adapter
Inline Yes
Corded Yes
Pole Format 2
Tripping Time 40ms
IP Rating IP40
Current Rating 10A
Voltage Rating 230 V ac
8 In stock for FREE next working day delivery
Price Each
£ 48.96
(exc. VAT)
£ 58.75
(inc. VAT)
Units
Per unit
1 - 11
£48.96
12 - 24
£46.02
25 +
£44.05
Related Products
The FN9255 IEC inlet filter incorporates a dual ...
Description:
The FN9255 IEC inlet filter incorporates a dual stage filter into an IEC inlet that offers excellent filter attenuation in a compact housing. Using an IEC inlet, at the point of entry offers an optimized position and practical solution for integrating an EMC filter into any system. A wide selection ...
The FN9255 IEC inlet filter incorporates a dual ...
Description:
The FN9255 IEC inlet filter incorporates a dual stage filter into an IEC inlet that offers excellent filter attenuation in a compact housing. Using an IEC inlet, at the point of entry offers an optimized position and practical solution for integrating an EMC filter into any system. A wide selection ...
Personal Residual Current Device - Safety PRCD-S is ...
Description:
Personal Residual Current Device - Safety PRCD-S is a mobile safety device for all building and installation sites aligned to regulationand the accident prevention regulations of the fire brigades PRCD-S allows the absolutely safe connection to existing socket outlets PRCD-S checks the correct socket outlet function, especially protective earth, and ...
RCD for the protection of personnel using permanent ...
Description:
RCD for the protection of personnel using permanent or semi-permanent equipment on many commercial and industrial applications. Suitable for BS/European power supply systems Robust construction Double pole breaking Mechanical flag to indicate contact position Separate test and reset buttons Connections via terminals Tripping current: 30m ATripping time: 40ms.