Product Details

Open Style with Leads, 15VA to 1000VA

High-quality open style toroidal transformers with a single 230 Vac 50/60 Hz primary winding. Twin secondary windings may be connected in series or parallel or used independently.

Small size and low weight compared with traditional stacked lamination types
Extremely low level of radiated magnetic field and very low induced noise (hum)
Very low iron losses
Double insulated primary leads
100% electrical and flash tested
High-quality manufacturing and testing in accordance to EN61558, EN60950, EN60065, VDE 0551, VDE 0550 and BS415

Standards

UL 506; EN 61558

Supplied with

Full mounting kit

//media.rs-online.com/t_line/L223845-01.gif
//media.rs-online.com/t_line/LF223775-10.gif

Approvals

UL 506; EN 61558

Standards

EN61558; EN60950; EN60065; BS415

Warning

  • Under no circumstances should both ends of the fixing bolt simultaneously contact the metal chassis or framework as this would create a potentially dangerous 'shorted-turn'.
Specifications
Attribute Value
Primary Voltage Rating 230V ac
Secondary Voltage Rating 2 x 18V ac
Power Rating 160VA
Number of Outputs 2
Secondary Current 4.44A
Height 42mm
Weight 1.5kg
Diameter 105mm
Dimensions 105 (Dia.) x 42mm
Maximum Operating Frequency 450Hz
Termination Type Copper Conductor Termination Wire
Minimum Temperature 0°C
Maximum Temperature +120°C
Isolation Voltage 4.5kV ac
91 In stock - FREE next working day delivery available
Price Each
£ 53.17
(exc. VAT)
£ 63.80
(inc. VAT)
Units
Per unit
1 - 24
£53.17
25 +
£47.85
Related Products
Compound-wound, with seal between first / second winding. ...
Description:
Compound-wound, with seal between first / second winding.
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins100% electrical and flash tested Low inter-winding capacitance Low radiated noise Extra fixing ...
230Va.c. 50 to 60Hz primary Single or twin ...
Description:
230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will ...