Nuvotem Talema 230V ac, 2 x 15V ac Toroidal Transformer, 15VA 2 Output

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

Open Style with Leads, 15VA to 1000VA

High-quality open style toroidal transformers with a single 230 Vac 50/60 Hz primary winding. Twin secondary windings may be connected in series or parallel or used independently.

Small size and low weight compared with traditional stacked lamination types
Extremely low level of radiated magnetic field and very low induced noise (hum)
Very low iron losses
Double insulated primary leads
100% electrical and flash tested
High-quality manufacturing and testing in accordance to EN61558, EN60950, EN60065, VDE 0551, VDE 0550 and BS415

Standards

UL 506; EN 61558

Supplied with

Full mounting kit

//media.rs-online.com/t_line/L223845-01.gif
//media.rs-online.com/t_line/LF223775-10.gif

Approvals

UL 506; EN 61558

Standards

EN61558; EN60950; EN60065; VDE 0551; VDE 0550; BS415

Warning

  • Under no circumstances should both ends of the fixing bolt simultaneously contact the metal chassis or framework as this would create a potentially dangerous 'shorted-turn'.
Specifications
Attribute Value
Primary Voltage Rating 230V ac
Secondary Voltage Rating 2 x 15V ac
Power Rating 15VA
Number of Outputs 2
Secondary Current 500mA
Height 31mm
Weight 300g
Diameter 60mm
Dimensions 60 (Dia.) x 31mm
Maximum Operating Frequency 450Hz
Termination Type Copper Conductor Termination Wire
Minimum Temperature 0°C
Isolation Voltage 4.5kV ac
Maximum Temperature +120°C
Available to back order for despatch 02/11/2020
Price Each
£ 16.06
(exc. VAT)
£ 19.27
(inc. VAT)
Units
Per unit
1 - 24
£16.06
25 +
£14.44
Related Products
PCB mounting mains transformers with a single 230Va.c. ...
Description:
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Thermal fuse in primary providing overload and short circuit protection Flame retardant materials to UL94-V0Fully ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins100% electrical and flash tested Low inter-winding capacitance Low radiated noise Extra fixing ...
Single and twin secondary windings for series or ...
Description:
Single and twin secondary windings for series or parallel connection Vacuum resin moulded to UL94-V0 rating Low inter-winding capacitance Low radiated noise100% electrical and flash tested Extra fixing points for secure board mounting (25 VA and 36 VA).