Product Details

Our Guardmaster® Safety t-ports/splitters, distribution boxes, shorting plugs, and taps are parts of a quick-disconnect system dedicated to machine safety. GuardLink™ taps connect safety input devices to a GuardLink system, a safety-based communications protocol that links safety to The Connected Enterprise. GuardLink enabled devices offer advanced features and diagnostics that can only be accessed through a GuardLink enabled connection tap.

Guardmaster Safety Relay DG: Dual GuardLink, 2.N.O, Instantaneous and Time

Guardmaster® safety connection systems are designed to:
Reduce installation cost
Ease system expansion
Simplify troubleshooting
Promote system modularity
Provide for Safety PLC input expansion
Support systems up to Category 3

Specifications
Attribute Value
Supply Voltage 26.4 V
Number of Channels 2
Function Safety Relay
Safety Contacts 2
Reset Method Automatic, Monitored Manual
Safety Category CAT III
Terminal Type Screw
Width 113.6mm
Length 22.5mm
Depth 119.14mm
4 In stock - FREE next working day delivery available
Price Each
£ 297.00
(exc. VAT)
£ 356.40
(inc. VAT)
Units
Per unit
1 +
£297.00
Related Products
Ensures correct switching of up to 3 contactors ...
Description:
Ensures correct switching of up to 3 contactors with monitoring Fail-safe internal monitoring Single channel input for use with interlock switches and emergency stop buttons. 3 uncommitted safety output circuits and provides a contactor monitoring facility and auxiliary output for indication purposes Power failure on safety critical internal faults result ...
EC type approved (applies when Safedge profiles are ...
Description:
EC type approved (applies when Safedge profiles are used in conjunction with a Safedge Evaluator)May be cut to size and fit Corner and straight connectors are "active" components - no "dead" zones The Safedge Evaluator monitors the status of the Safedge profile and provides an output of two fully cross ...
Unit monitors any number of mats that are ...
Description:
Unit monitors any number of mats that are connected together to form the safeguarded zone up to a total area of 100m². The Control Unit interfaces with the control circuitry of the machine and includes two safety relays for control redundancy. Detects presence on the mat and open/short circuit Cross-monitored ...
Ensures motor movement is at a preset limit ...
Description:
Ensures motor movement is at a preset limit before an output signal is given For use with guard locking interlock switches Fault tolerant principle control unit Monitors contactor operation Dimensions: H73 x W45 x D120mm. CU3 Timing Control Unit, Back EMF Monitor, Slow Motion Detection.