Telemecanique Sensors for Various Media Differential

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CH
Product Details

Adjustable electromechanical pressure switches from basic pressure transmitters to configurable pressure switches for pumping, hydraulic, and HVAC machinery

Electronic pressure sensors OsiSense XM XMLP pressure transmitters Compact metal body, 316L stainless steel fluid entry With analogue output. Sizes in bar

Specifications
Attribute Value
Pressure Reading Type Differential
Maximum Pressure Reading 75bar
Accuracy ±0.5 %
Output Type Analogue
Media Measured Air, Fresh Water, Gas, Hydraulic Oil, Refrigeration Fluid
Process Connection G1/4
Analogue Output 0 <arrow/> 10 V
Electrical Connection 4-Pin M12 Male Connector
Response Time ≤2 ms
Maximum Current <lt/>7 mA
Supply Voltage 24 V dc
Housing Material FPM, Stainless Steel
IP Rating IP65, IP67, IP69K
Minimum Pressure Setting 0bar
Maximum Pressure Setting 25bar
Minimum Operating Temperature -30°C
Series XMLP
Maximum Operating Temperature +85°C
Mounting Type Cable Mount
Available to back order for despatch 24/01/2020
Price Each
£ 95.00
(exc. VAT)
£ 114.00
(inc. VAT)
Units
Per unit
1 +
£95.00
Related Products
Osisense XMP pressure sensors are for control circuits ...
Description:
Osisense XMP pressure sensors are for control circuits and are used to control the pressure of water (sea and fresh) and air. XMP series pressure sensors have an adjustable differential and are for regulation between two thresholds. Diaphragm pressure actuatorG 1/4 (female) fluid connection type2 cable entries tapped for Pg ...
Pressure sensor XMLK - 0..10bar - G 1/4A ...
Description:
Pressure sensor XMLK - 0..10bar - G 1/4A - 0..10V - M12 - set of 1. Adjustable electromechanical pressure switches, in which we are a recognized leader in industrial applications Electronic pressure sensors and switches with a full range from basic pressure transmitters to configurable pressure switches for pumping, hydraulic, ...
Schneider Electric XMLA pressure switches for control circuits ...
Description:
Schneider Electric XMLA pressure switches for control circuits are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam, corrosive fluids, or viscous products. The XMLA pressure and vacuum switches have a fixed differential and are for detection of a single threshold. Fixed differential External pressure ...
Simple and robust construction Adjustable switching point through ...
Description:
Simple and robust construction Adjustable switching point through headless screw Suitable for compressed air, hydraulic oil, oil emulsions, water Available as NO, NC or changeover.