TDK-Lambda DRM40 Series Redundancy Module for use with EMC Filter, EMI Filter

  • RS Stock No. 186-0211
  • Mfr. Part No. DRM-40
  • Brand TDK-Lambda
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): MY
Product Details

The DRM40 series of 20 to 40A DIN rail mount redundancy modules can be used in N+1 redundancy applications or to parallel two power supplies for additional power. The DRM40 has a current balancing LED indicator which is illuminated when both power supplies have been adjusted to deliver the same current. Two isolated alarm signals indicate the output voltage status of each power supply. Internally the DRM40 has a low 200mV voltage drop.

Compact Size
Low 200mV Voltage Drop 
Current Balance Indicator Option 
Isolated Alarm Signals
Applications
General Purpose Industrial
Test & Measurement

Specifications
Attribute Value
Accessory Type Redundancy Module
Series DRM40
For Use With EMC Filter, EMI Filter
Supply Voltage 10 → 30V dc
Input Current Range 2 X 20 A, 60 (Peak) A
Mounting Style DIN Rail Mount
17 In stock for FREE next working day delivery
Price Each
£ 65.10
(exc. VAT)
£ 78.12
(inc. VAT)
Units
Per unit
1 +
£65.10
Related Products
Active redundancy module for superior system availability and ...
Description:
Active redundancy module for superior system availability and maximum operational reliability. QUINT S-ORING enables the separate structuring of a redundant system. In combination with the new QUINT POWER power supply, the redundant system is monitored continuously. Consistent redundancy up to the load Input voltage and decoupling section monitored on a ...
20A Enclosed Redundancy Module to improve overall system ...
Description:
20A Enclosed Redundancy Module to improve overall system operation reliability, Support 1+1 and N+1 redundancy system, 2 channels input and 1 output, DC OK, Input 48Vdc. Support 1+1 and N+1 redundancy system2 channels inout and 1 output Suitable for redundancy operation of 5V/12V/24V/48V system Output current up to 20ACooling by ...
Using a redundancy module, it is possible for ...
Description:
Using a redundancy module, it is possible for two power supply units of the same type connected in parallel on the,output side to increase performance or for redundancy to be 100% isolated from one another. Decoupling power supply units switched in parallel Installation in potentially explosive areas is permitted Load ...
For N+1 and 1+1 Redundant Systems Dual Input ...
Description: