Fluke 6500 PAT Testing Kit, Kit Contents APP 1000 Barcode Appliance Number Labels, DMS 0702 Software, Fail 100s

  • RS Stock No. 797-6711
  • Mfr. Part No. 6500-2 UK KIT
  • Brand Fluke
Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): NL
Product Details

Fluke 6500-2 PAT Kit UK Version

The Fluke 6500-2 PAT tester is a low weight, small size, one-touch solution with redesigned auto-test capabilities to help you increase the number of portable appliance tests completed each day. The 6500-2 is designed to enable you to work faster without compromising test results. Pre-set test routines are initiated from a single button. This not only simplifies testing but also facilitates a faster, more efficient way of working. The fully automatic 6500-2 also includes user-definable test routines and a QWERTY keyboard for rapid data entry.

Features & Benefits

With powerful auto test capabilities and simplified controls, including ’one touch’ test routines, the Fluke 6500-2 PAT Tester increases the number of tests you can perform per day without compromising results
The Fluke 6500-2 is suitable for testing both 230 V and 110 V appliances,the 6500-2 model runs all the required safety tests: Earth bond low (low/high current, Insulation 500 V, 250 V, Leakage (PE current, touch current, substitute current), Can test 110 V appliances (earth bond, insulation) via the 110 V adapter kit
Integral QWERTY keyboard for rapid data entry
Memory for back-up data storage and USB port for transfer to PC
Large backlit graphics display
Pre-set, auto-test sequences for user convenience
Integral site, location and description codes for faster data processing
Memory review facility for more on-site control
Dedicated key for each test for ’one-touch’ testing
Pre-set pass/fail levels to save time
Large display for easy reading
Single mains socket for appliance connection
Separate IEC socket for easy mains/extension lead testing
Detachable test leads for quick field replacement
Integral carrying handle
Dimensions: 200 x 275 x 114 mm
Weight: 3.13 kg

Test specifications

Power-on test
Earth bond test (Rpe)
Insulation test (RISO)
Touch current test
Substitute leakage current
RCD Test: trip current
RCD Test: trip time
Load/Leakage test: load current
Load/Leakage test: load power display range 230 V mains
Load/Leakage test: Leakage current
PELV test

Standards

Complies with EN61010-1 3rd edition CAT II, 300 V, pol 2

Supplied with

SPSCAN6000 Barcode Scanner, APP 1000 Barcode Appliance Number Labels, Fail 100s Appliance Fail Labels, Pass 560R Appliance Pass Labels, EXTL 100 Extension Lead Test Adaptor, DMS 0702 Software, Hard Carry Case.

Specifications
Attribute Value
Model Number 6500
Tester Type Dual Voltage PAT
Test Type Class I, Class II
Testing Method Automatic
Download Yes
Kit Contents APP 1000 Barcode Appliance Number Labels, DMS 0702 Software, Fail 100s Appliance Fail Labels, Hard Carry Case, Pass 560R Appliance Pass Labels, SPSCAN6000 Barcode Scanner
Calibrated RSCAL
Power Source Mains
Dimensions 200 x 275 x 100mm
Weight 3kg
Height 100mm
Width 275mm
Length 200mm
Minimum Operating Temperature 0°C
Maximum Supply Voltage 230V
Maximum Operating Temperature +40°C
Available to back order for despatch 19/12/2019
Price Each
Was £2,102.00
£ 1,899.50
(exc. VAT)
£ 2,279.40
(inc. VAT)
Units
Per unit
1 +
£1,899.50
Not available for guaranteed pre 9am/10am delivery
Related Products
Fluke 179 True RMS digital multimeter kit is ...
Description:
Fluke 179 True RMS digital multimeter kit is the preferred choice for electrical engineers, industrial and commercial electricians. Fluke 179 multimeter offers a digital display with analogue bar graph, backlight and built in temperature measurements. Contains features to help you troubleshoot and repair electrical and electronic systems. This small, lightweight ...
Offering data storage and download capabilities via a ...
Description:
Offering data storage and download capabilities via a USB port, the Fluke 1625-2 can perform 4 types of earth ground measurement. This tester is able to measure ground loop resistance using only clamps, this method doesn't require the use of earth ground stakes or disconnection of ground rods. Making this ...
Earth loop impedance testers to verify the loop ...
Description:
Earth loop impedance testers to verify the loop impedance of a live electrical circuit without the need to disconnect the electrical supply. The LTW300 series instruments offer a safe and easy 2 wire loop testing solution that does not trip 30mA RCDs and can be used on a wide range ...
The Seaward apollo 600 + elite bundle PAT ...
Description:
The Seaward apollo 600 + elite bundle PAT tester kit has a built-in risk assessment tool for any workplace hazard. It has a variety of testing and inspection reports including portable appliance testing, fire detection and emergency lighting. This comprehensive device also offers an integrated solution to managing a risk-based ...