Siemens PLC Power Supply 3RX950 Series AS-I Power Supply Unit, 120 V ac, 230 → 500 V ac, 30V dc, 8 A 125 x 120 x

  • RS Stock No. 746-6081
  • Mfr. Part No. 3RX9503-0BA00
  • Brand Siemens
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): RO
Product Details

AS-i Power Supply - 3RX950 Series

AS-i Power Supplies for 35 mm DIN rail mounting

Integrated ground fault detection
Integrated overload detection
Remote reset and indication
LED status indication
IP20 rated

Approvals

CE, UL

//media.rs-online.com/t_line/L316042-01.gif

Siemens Power Supply Module

The Siemens 30Vdc power supply module is designed to use with AS-interface PLCs. The supply line voltage ratings are 120Vac/230Vac and output current is 8A.
Actuator Sensor Interface, AS-I
AS-I is a method of providing communication from simple discrete components such as an inductive sensor or switching valve via a simple two-wire network to a controlling device such as a PLC or PC.
A unique feature of the AS-I system is the flat, two-core cable (stock no 242-6189) designed to enable fast and easy connection, ensuring correct polarity every time. The cable can be used in a network up to 100m (300m if repeaters are used).
By providing power and data down the same cable, the amount of time normally used to connect sensors and actuators is dramatically reduced, thereby providing savings in cable requirements and man-hours.
The choice of AS-I connection modules enables the user to connect standard sensors/actuators to the BUS with all the address benefits of using dedicated sensors/actuators. It also serves to increase the number of I/O nodes that are available to the user by the use of addressable splitter boxes. The connection modules are available in a variety of packages and can accommodate up to 4 inputs and 4 outputs. This enables up to 124 inputs and 124 outputs to be connected to a single AS-I network.
Another feature of the AS-I system is the method by which the sensors or modules communicate with the host. The design of the communications protocol ensures high data accuracy and error detection capabilities, making the ASI system ideal for automation in noisy and industrial environments.
Benefits of AS-I
Replaces hard wiring
High data speed
Low-cost installation
Intelligent diagnostics
Easy to learn and install
Highly flexible
Can connect to other Fieldbus systems
User-friendly
Off-site pre-assembly and test
Easy maintenance
Faster on-site commissioning
Host or stand-alone use
Able to use standard sensors and actuators (using modules)

Features and Benefits

• Easy to learn and install
• Integrated short circuit protection.
• Intelligent diagnostics
• Integrated overload detection
• Easy maintenance
• Faster onsite commissioning
• Ambient operating temperature ranges between -10°C 70°C

Applications


Industrial automation
• Robotics
• Automobile industry

Certifications


IP20 rated
• UL certified
• EAC certified

Actuator Sensor Interface (AS-I)

Actuator Sensor Interface, AS-I

AS-I is a method of providing communication from simple discrete components such as an inductive sensor or switching valve via a simple two-wire network to a controlling device such as a PLC or PC.
A unique feature of the AS-I system is the flat, two-core cable (stock no 242-6189) designed to enable fast and easy connection, ensuring correct polarity every time. The cable can be used in a network up to 100m (300m if repeaters are used).
By providing power and data down the same cable, the amount of time normally used to connect sensors and actuators is dramatically reduced, thereby providing savings in cable requirements and man-hours.
The choice of AS-I connection modules enables the user to connect standard sensors/actuators to the BUS with all the address benefits of using dedicated sensors/actuators. It also serves to increase the number of I/O nodes that are available to the user by the use of addressable splitter boxes. The connection modules are available in a variety of packages and can accommodate up to 4 inputs and 4 outputs. This enables up to 124 inputs and 124 outputs to be connected to a single AS-I network.
Another feature of AS-I system is the method by which the sensors or modules communicate with the host. The design of the communications protocol ensures high data accuracy and error detection capabilities, making the ASI system ideal for automation in noisy and industrial environments.

Benefits of AS-I

Replaces hard wiring
High data speed
Low cost installation
Intelligent diagnostics
Easy to learn and install
Highly flexible
Can connect to other fieldbus systems
User-friendly
Off-site pre-assembly and test
Easy maintenance
Faster on-site commissioning
Host or stand alone use
Able to use standard sensors and actuators (using modules)

Specifications
Attribute Value
Manufacturer Series 3RX950
For Use With AS-I Power Supply Unit
Line Voltage 120 V ac, 230 → 500 V ac
User Power Output Voltage 30V dc
Output Current 8 A
Length 125mm
Width 120mm
Depth 125mm
Dimensions 125 x 120 x 125 mm
5 in stock for FREE next working day delivery
5 available from Europe for delivery within 1 working day(s)
Price Each
£ 413.92
(exc. VAT)
£ 496.70
(inc. VAT)
Units
Per unit
1 +
£413.92
Related Products
Quantum power supply modules serve two main functions ...
Description:
Quantum power supply modules serve two main functions - they provide power to the system rack and also protect the system from noise and voltage swings. Power supply modules feature both overcurrent and overvoltage protection. They are able operate in most electrically noisy environments without the need for external isolation ...
Compact and easy-to-use system that is fully compatible ...
Description:
Compact and easy-to-use system that is fully compatible with the Telemecanique range of control gear, detectors, pushbuttons etc. Instruction sets include: up/down counters and timers, registers, arithmetic functions, pulsed or PWM output function, comparison function, controllers.
Three memory cassettes that can be installed into ...
Description:
Three memory cassettes that can be installed into the FX3U CPU, and when installed the memory cassette's internal program is used in place of the internal RAM memory. The FX3U-FLROM-64L (stock no. 539-0853) features program transfer buttons to allow permanent overwriting of the RAM based-program. FX3U battery – this battery ...
AC input power supply unit designed to provide ...
Description:
AC input power supply unit designed to provide 5Vdc necessary for Q series modules. Once plugged into the backplane, all Q series modules on the same backplane will be powered from this unit. Built-in error relay for diagnosis outside the control cabinetLarge 6A capacity allows systems to be constructed with ...