9V ac 1 Output Through Hole PCB Transformer, 16VA

  • RS Stock No. 732-0449
  • Mfr. Part No. VC 16/1/9
  • Brand Block
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

PCB Mount 230Vac Primary VC/VCM Series

Single and twin secondary windings for series or parallel connection
Vacuum resin moulded to UL94-V0 rating
Low inter-winding capacitance
Low radiated noise
100% electrical and flash tested
Extra fixing points for secure board mounting (25 VA and 36 VA)

Note

To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series.

Standards

EN 61 558 IEC 61558

Approvals

ENEC, UL recognised

//media.rs-online.com/t_line/L347248-01.gif
//media.rs-online.com/t_line/L7320547-01.gif

Approvals

VDE; UL

Standards

EN 61 558; IEC 61558

Specifications
Attribute Value
Secondary Voltage Rating 9V ac
Power Rating 16VA
Primary Voltage Rating 230V ac
Number of Outputs 1
Length 57mm
Width 48mm
Depth 39mm
Dimensions 57 x 48 x 39mm
Weight 420g
Mounting Type Through Hole
Maximum Temperature +40°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
27 In stock for FREE next working day delivery
Price Each
£ 6.99
(exc. VAT)
£ 8.39
(inc. VAT)
Units
Per unit
1 - 9
£6.99
10 - 24
£6.71
25 - 49
£6.16
50 +
£5.62
Related Products
Fully shrouded bobbins Extra pins for secure board ...
Description:
Fully shrouded bobbins Extra pins for secure board mounting 100% electrical and flash tested Tested in accordance with BS3535 and EN 60 742.
230Va.c. 50 to 60Hz primary Single or twin ...
Description:
230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.
From Myyra, the 44000 Series of type EI ...
Description:
From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable. • Professional safety transformers with insulation above 4000V.• For installation on printed ...