15V ac 1 Output Through Hole PCB Transformer, 10VA

  • RS Stock No. 732-0433
  • Mfr. Part No. VC 10/1/15
  • Brand Block
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

PCB Mount 230Vac Primary VC/VCM Series

Single and twin secondary windings for series or parallel connection
Vacuum resin moulded to UL94-V0 rating
Low inter-winding capacitance
Low radiated noise
100% electrical and flash tested
Extra fixing points for secure board mounting (25 VA and 36 VA)

Note

To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series.

Standards

EN 61 558 IEC 61558

Approvals

ENEC, UL recognised

//media.rs-online.com/t_line/L347248-01.gif
//media.rs-online.com/t_line/L7320547-01.gif

Approvals

VDE; UL

Standards

EN 61 558; IEC 61558

Specifications
Attribute Value
Secondary Voltage Rating 15V ac
Power Rating 10VA
Primary Voltage Rating 230V ac
Number of Outputs 1
Length 51mm
Width 43mm
Depth 34.6mm
Dimensions 51 x 43 x 34.6mm
Weight 280g
Mounting Type Through Hole
Maximum Temperature +40°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
26 In stock for FREE next working day delivery
Price Each
£ 5.31
(exc. VAT)
£ 6.37
(inc. VAT)
Units
Per unit
1 - 9
£5.31
10 - 24
£5.11
25 - 49
£4.70
50 +
£4.29
Related Products
PCB mounting mains transformers with a single 230Va.c. ...
Description:
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Fully shrouded bobbins Extra pins for secure board mounting 100% electrical and flash tested Tested ...
RS Pro PCB Standard transformers are low voltage ...
Description:
RS Pro PCB Standard transformers are low voltage mains transformers with a single 230 VAC 50/60Hz primary windingThese transformers have secondary windings suitable for series/ parallel connection to give a wide range of current options. They are 100% electric and flash tested. Double section bobbin, high efficiency and low temperature ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.