5V 1 Output Surface Mount PCB Transformer

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

MID-PPTI Push-Pull Transformers for Texas Instruments

Small size
Surface mount
Low profile
Operating temp: -40°C to 125°C
Functional, supplementary or reinforced insulation
Applications
Isolated interface power supply for CAN, RS-485, RS-422, RS-232, SPI, I2C, lower-power LAN
Industrial automation
Process control
Medical equipment
PLC analog and digital I/O modules
Isolated gate driver power supplies
AC motor drives
Uninterruptible power supplies (UPS)
Solar inverters
Polyphase energy meters
Protection relays and IEDs

Specifications
Attribute Value
Secondary Voltage Rating 5V
Primary Voltage Rating 5V dc
Number of Outputs 1
Length 8mm
Width 7.62mm
Depth 9.14mm
Dimensions 8 x 7.62 x 9.14mm
Mounting Type Surface Mount
Minimum Temperature -40°C
Maximum Temperature +125°C
Minimum Operating Frequency 250kHz
Maximum Operating Frequency 550kHz
Available to back order for despatch 17/03/2020
Price Each (On a Reel of 500)
£ 2.018
(exc. VAT)
£ 2.422
(inc. VAT)
Units
Per unit
Per Reel*
500 +
£2.018
£1,009.00
*price indicative
Related Products
The HSZ series transformers have been designed for ...
Description:
The HSZ series transformers have been designed for applications where for various reasons the mounting of the transformer needs to be on the outside of the panel, whether this is due to space or heat issues. The series has a +80 °C rise and as standard have copper winding for ...
MID-IBMAX Isolated Buck Transformers for Maxim Integrated Iso-Buck ...
Description:
MID-IBMAX Isolated Buck Transformers for Maxim Integrated Iso-Buck Chipsets. No optocoupler used for feedback Primary side regulation Reduces number of components ApplicationsFactory automation Programmable Logic Controllers (PLCs)Isolated Communications Interface like RS485, RS232.
230Va.c. 50 to 60Hz primary Single or twin ...
Description:
230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will ...
Single and twin secondary windings for series or ...
Description:
Single and twin secondary windings for series or parallel connection Vacuum resin moulded to UL94-V0 rating Low inter-winding capacitance Low radiated noise100% electrical and flash tested Extra fixing points for secure board mounting (25 VA and 36 VA).