9V ac 2 Output Through Hole PCB Transformer, 16VA

  • RS Stock No. 174-0068
  • Mfr. Part No. 44308
  • Brand Myrra
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): FR
Product Details

Type EI 54 / 18.8 → 16 VA transformers

Secondary voltages are nominal load voltages on resistive loads.

Approvals

UL, VDE

Encapsulated – Toroidal

Note

Fixing screws not provided

Specifications
Attribute Value
Secondary Voltage Rating 9V ac
Power Rating 16VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 56.5mm
Width 47.25mm
Depth 38.75mm
Dimensions 56.5 x 47.25 x 38.75mm
Weight 400g
Mounting Type Through Hole
Maximum Temperature +50°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
35 In stock for delivery within 1 working days
Price Each
£ 7.13
(exc. VAT)
£ 8.56
(inc. VAT)
Units
Per unit
1 - 24
£7.13
25 - 49
£6.43
50 - 99
£6.12
100 - 249
£5.80
250 +
£5.52
Not available for guaranteed pre 9am/10am delivery
Related Products
Safety isolating and isolating control transformers Twin secondary ...
Description:
Safety isolating and isolating control transformers Twin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN rail All units have 4 hole panel mount fixings Easy installation 4mm² cage clamp terminals Insulation catagory Class B. Safety Isolating Transformer.
Use as power, safety or displacement transformers in ...
Description:
Use as power, safety or displacement transformers in accordance with the applicable EN norm High short-term performance Low switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main side Electrically isolated coils Screw terminal connectors. Control transformers, 1-phase, 4AM Series.
PCB mounting mains transformers with a single 230Va.c. ...
Description:
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Thermal fuse in primary providing overload and short circuit protection Flame retardant materials to UL94-V0Fully ...
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins100% electrical and flash tested Low inter-winding capacitance Low radiated noise Extra fixing ...