2 x 12V ac 2 Output Through Hole PCB Transformer, 2VA

  • RS Stock No. 173-9737
  • Mfr. Part No. 44129
  • Brand Myrra
Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): FR
Product Details

Type EI 30 - 1 VA → 2.3 VA series 44000 transformers

From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable.

Features and Benefits:

• Professional safety transformers with insulation above 4000V.
• For installation on printed circuit boards (according to European grid).
• Coupling in series or parallel.
• Vacuum-filled with resin to ensure materials withstand aging.
• Unit and 100% control on automated line.
• Secondary voltages are nominal load voltages on resistive loads.

Standards

UL 94-V0; VDE 0551; IEC 742

Approvals

UL, VDE

Encapsulated – Toroidal

Note

Fixing screws not provided

Specifications
Attribute Value
Secondary Voltage Rating 2 x 12V ac
Power Rating 2VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 32.6mm
Width 27.6mm
Depth 27.3mm
Dimensions 32.6 x 27.6 x 27.3mm
Weight 100g
Mounting Type Through Hole
Maximum Temperature +70°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
11 in stock for FREE next working day delivery
85 available from Europe for delivery within 1 working day(s)
Price Each
£ 3.14
(exc. VAT)
£ 3.77
(inc. VAT)
Units
Per unit
1 - 24
£3.14
25 - 49
£3.01
50 - 99
£2.87
100 - 249
£2.74
250 +
£2.61
Related Products
Fully shrouded bobbins Extra pins for secure board ...
Description:
Fully shrouded bobbins Extra pins for secure board mounting 100% electrical and flash tested Tested in accordance with BS3535 and EN 60 742.
RS Pro PCB Standard transformers are low voltage ...
Description:
RS Pro PCB Standard transformers are low voltage mains transformers with a single 230 VAC 50/60Hz primary winding These transformers have secondary windings suitable for series/ parallel connection to give a wide range of current options. They are 100% electric and flash tested. Double section bobbin, high efficiency and low ...
Single and twin secondary windings for series or ...
Description:
Single and twin secondary windings for series or parallel connection Vacuum resin moulded to UL94-V0 rating Low inter-winding capacitance Low radiated noise100% electrical and flash tested Extra fixing points for secure board mounting (25 VA and 36 VA).
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.