18V ac 2 Output Through Hole PCB Transformer, 30VA

  • RS Stock No. 173-9434
  • Mfr. Part No. 45065
  • Brand Myrra
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): FR
Product Details

Type UI 39 - 10 VA → 30 VA

Secondary voltages are nominal load voltages on resistive loads.
Only the pins indicated on the wiring diagram "physically" exist.

Standards

IEC 742, VDE 0551, SEV 1003

Approvals

UL 506

Encapsulated – Toroidal

Note

Fixing screws not provided

Specifications
Attribute Value
Secondary Voltage Rating 18V ac
Power Rating 30VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 68mm
Width 57mm
Depth 35mm
Dimensions 68 x 57 x 35mm
Weight 550g
Mounting Type Through Hole
Maximum Temperature +50°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
16 In stock for delivery within 1 working days
Price Each
£ 11.30
(exc. VAT)
£ 13.56
(inc. VAT)
Units
Per unit
1 - 24
£11.30
25 - 49
£10.35
50 - 99
£9.56
100 - 249
£8.88
250 +
£8.28
Not available for guaranteed pre 9am/10am delivery
Related Products
Chassis mounting low voltage mains transformers with a ...
Description:
Chassis mounting low voltage mains transformers with a single 230Va.c. 50/60Hz primary winding. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction Fully shrouded bobbins Full varnish impregnation Two hole fixing wrap-over ...
RS Pro PCB Standard transformers are low voltage ...
Description:
RS Pro PCB Standard transformers are low voltage mains transformers with a single 230 VAC 50/60Hz primary winding These transformers have secondary windings suitable for series/ parallel connection to give a wide range of current options. They are 100% electric and flash tested. Double section bobbin, high efficiency and low ...
From Myyra, the 44000 Series of type EI ...
Description:
From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable. • Professional safety transformers with insulation above 4000V.• For installation on printed ...
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins100% electrical and flash tested Low inter-winding capacitance Low radiated noise Extra fixing ...