8V ac 2 Output Through Hole PCB Transformer, 14VA

  • RS Stock No. 170-7363
  • Mfr. Part No. FL 14/8
  • Brand Block
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

PCB Mounting Low Profile 115 / 230Vac Primary

Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection
Twin secondary windings for series or parallel connection
Low profile compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
Low inter-winding capacitance
Low radiated noise
Extra fixing holes for secure board mounting
Standard: EN60742, VDE 0551, IEC 61558

Note

Transformer with 2 x 24V outputs are not VDE, SEV approved.

Standards

VD 61 558

Approvals

VDE; UL

Standards

VD 61 558

Specifications
Attribute Value
Secondary Voltage Rating 8V ac
Power Rating 14VA
Primary Voltage Rating 115 V ac, 230 V ac
Number of Outputs 2
Length 68mm
Width 24.4mm
Depth 57mm
Dimensions 68 x 24.4 x 57mm
Weight 315g
Mounting Type Through Hole
Maximum Temperature +40°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Available to back order for despatch 31/03/2020
Price Each (In a Tray of 20)
£ 9.594
(exc. VAT)
£ 11.513
(inc. VAT)
Units
Per unit
Per Tray*
20 +
£9.594
£191.88
*price indicative
Related Products
Twin 115Va.c. 50/60Hz primary windings which may be ...
Description:
Twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation Fully shrouded bobbins100% electrical and flash tested Tested in accordance with BS3535 and EN 60 742.
Fully shrouded bobbins Extra pins for secure board ...
Description:
Fully shrouded bobbins Extra pins for secure board mounting 100% electrical and flash tested Tested in accordance with BS3535 and EN 60 742.
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.
From Myyra, the 44000 Series of type EI ...
Description:
From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable. • Professional safety transformers with insulation above 4000V.• For installation on printed ...