2 x 9V ac 2 Output PCB Mount PCB Transformer, 1.5VA

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

RS Pro PCB Standard Transformers

RS Pro PCB Standard transformers are low voltage mains transformers with a single 230 VAC 50/60Hz primary winding
These transformers have secondary windings suitable for series/ parallel connection to give a wide range of current options. They are 100% electric and flash tested. Double section bobbin, high efficiency and low temperature rise. These RS Pro transformers have low interwinding capacity and low radiated noise.

Specifications
Attribute Value
Secondary Voltage Rating 2 x 9V ac
Power Rating 1.5VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 32.5mm
Width 27.5mm
Depth 24mm
Dimensions 32.5 x 27.5 x 24mm
Weight 85g
Mounting Type PCB Mount
Maximum Temperature +130°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Available to back order for despatch 22/06/2020
Price Each
£ 3.19
(exc. VAT)
£ 3.83
(inc. VAT)
Units
Per unit
1 - 9
£3.19
10 +
£2.86
Related Products
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz ...
Description:
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction ...
Chassis mounting low voltage mains transformers with a ...
Description:
Chassis mounting low voltage mains transformers with a single 230Va.c. 50/60Hz primary winding. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction Fully shrouded bobbins Full varnish impregnation Two hole fixing wrap-over ...
Twin 115Va.c. 50/60Hz primary windings which may be ...
Description:
Twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation Fully shrouded bobbins100% electrical and flash tested Tested in accordance with BS3535 and EN 60 742.
230Va.c. 50 to 60Hz primary Single or twin ...
Description:
230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will ...