12V ac 2 Output Through Hole PCB Transformer, 12VA

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

PCB Mounting, Flame Retardant Transformer with Thermal Fuse

Thermal fuse in primary providing overload and short circuit protection
Flame retardant materials to UL94-V0
Fully shrouded windings
Extra pins for secure board mounting
Designed and tested in accordance with EN 61558 (EN 60742) EN 60950

//media.rs-online.com/t_line/L805502-01.gif

Approvals

8888

Standards

EN 61558 (EN 60742); EN 60950

Open Frame - Laminated

PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section metric bobbin constructionFull varnish impregnation

Specifications
Attribute Value
Secondary Voltage Rating 12V ac
Power Rating 12VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 54mm
Width 45mm
Depth 41mm
Dimensions 54 x 45 x 41mm
Weight 400g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
349 In stock for FREE next working day delivery
Price Each
£ 8.35
(exc. VAT)
£ 10.02
(inc. VAT)
Units
Per unit
1 - 24
£8.35
25 +
£7.35
Related Products
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz ...
Description:
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction ...
Chassis mounting low voltage mains transformers with a ...
Description:
Chassis mounting low voltage mains transformers with a single 230Va.c. 50/60Hz primary winding. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction Fully shrouded bobbins Full varnish impregnation Two hole fixing wrap-over ...
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins100% electrical and flash tested Low inter-winding capacitance Low radiated noise Extra fixing ...
230Va.c. 50 to 60Hz primary Single or twin ...
Description:
230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will ...