9V ac 2 Output Through Hole PCB Transformer, 6VA

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

230 Vac Primary Transformers

Fully shrouded bobbins
Extra pins for secure board mounting
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Insulation Class B (130°C)
Isolation (Primary to Secondary) 4 kV rms
Isolation (Windings to core) 2 kV rms
Pin Length x Diameter 5 x 1 mm
Maximum Winding Temperature Rise +55°C
Input Voltage 230 Vac
//media.rs-online.com/t_line/L805502-01.gif

Approvals

8888

Standards

BS3535; EN 60 742

Open Frame - Laminated

PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section metric bobbin constructionFull varnish impregnation

Specifications
Attribute Value
Secondary Voltage Rating 9V ac
Power Rating 6VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 43mm
Width 36mm
Depth 33mm
Dimensions 43 x 36 x 33mm
Weight 180g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
580 In stock for FREE next working day delivery
Price Each
£ 5.04
(exc. VAT)
£ 6.05
(inc. VAT)
Units
Per unit
1 - 9
£5.04
10 - 24
£3.96
25 +
£3.72
Related Products
The two independent secondary windings may be connected ...
Description:
The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Optional terminal shrouds for 75VA and 100VA(503-928).
Twin 115Va.c. 50/60Hz primary windings which may be ...
Description:
Twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation Fully shrouded bobbins100% electrical and flash tested Tested in accordance with BS3535 and EN 60 742.
230Va.c. 50 to 60Hz primary Single or twin ...
Description:
230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.