20V ac 2 Output Through Hole PCB Transformer, 3VA

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

230 Vac Primary Transformers

Fully shrouded bobbins
Extra pins for secure board mounting
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

//media.rs-online.com/t_line/L805502-01.gif

Approvals

8888

Standards

BS3535; EN 60 742

Open Frame - Laminated

PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section metric bobbin constructionFull varnish impregnation

Specifications
Attribute Value
Secondary Voltage Rating 20V ac
Power Rating 3VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 38mm
Width 35mm
Depth 30mm
Dimensions 38 x 35 x 30mm
Weight 140g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
56 In stock - FREE next working day delivery available
Price Each
£ 6.22
(exc. VAT)
£ 7.46
(inc. VAT)
Units
Per unit
1 - 9
£6.22
10 - 24
£4.86
25 +
£4.56
Related Products
Power consumption 2.5VA, 50/60Hz Accuracy class120, 30 or ...
Description:
Power consumption 2.5VA, 50/60Hz Accuracy class120, 30 or 40mm busbar mounting Suitable for circular conductors 35mm aperture Maximum aperture for bar conductors 40x10mm (type 7)Operating temperature range –30 to +85°CSecondary terminals M5 studs with lock washers, nuts and terminal cover Full scale deflection currents can be selected by passing more ...
The HOBUT split-core current transformer has a unique ...
Description:
The HOBUT split-core current transformer has a unique clip-together feature enabling high-speed permanent installation and suitable for primary currents from 100A to 800A. It is for installation into existing networks without the need to disconnect cable circuits or busbars. The inbuilt plug-in short circuit link allows the CT to be ...
Primary current range 50-150A1% accuracy Operating frequency 50/60Hz ...
Description:
Primary current range 50-150A1% accuracy Operating frequency 50/60Hz Turns ratio 2500:1Rated burden resistance 33 ΩDielectric with stand voltage 4KVrms Operating temperature range -40 to +85ºCAll materials UL94-V0. Cable primary high accuracy current transformer. Low Cost Current Sense Transformers.
For AC and DC systems Type BTo detect ...
Description:
For AC and DC systems Type BTo detect earth faults in grounded voltage systems4 setting ranges from 10 mA to 3 AManual reset, with alarm and pre-warning With adjustable switching delay Energized or de-energized on trip LED indicator for operation, pre-alarm and alarm With test function LED-chain indicates fault current ...