5V ac 2 Output Through Hole PCB Transformer, 3VA

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

230 Vac Primary Transformers

Fully shrouded bobbins
Extra pins for secure board mounting
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Insulation Class B (130°C)
Isolation (Primary to Secondary) 4 kV rms
Isolation (Windings to core) 2 kV rms
Pin Length x Diameter 5 x 1 mm
Maximum Winding Temperature Rise +55°C
Input Voltage 230 Vac
//media.rs-online.com/t_line/L805502-01.gif

Approvals

8888

Standards

BS3535; EN 60 742

Specifications
Attribute Value
Secondary Voltage Rating 5V ac
Power Rating 3VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 38mm
Width 35mm
Depth 30mm
Dimensions 38 x 35 x 30mm
Weight 140g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
31 In stock for FREE next working day delivery
Price Each
£ 7.18
(exc. VAT)
£ 8.62
(inc. VAT)
Units
Per unit
1 - 9
£7.18
10 - 24
£6.07
25 +
£5.71
Related Products
Chassis mounting frame construction low voltage mains transformers ...
Description:
Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding. This range of single-phase single-winding safety and isolation transformer is primarily designed for use in repetitive applications.ABT 7 series transformers provide enhanced electrical isolation between the mains supply and the application. The whole range features ...
RS Pro PCB Standard transformers are low voltage ...
Description:
RS Pro PCB Standard transformers are low voltage mains transformers with a single 230 VAC 50/60Hz primary windingThese transformers have secondary windings suitable for series/ parallel connection to give a wide range of current options. They are 100% electric and flash tested. Double section bobbin, high efficiency and low temperature ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not ...