24V ac 2 Output Through Hole PCB Transformer, 3VA

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

PCB Mount 115/230Vac Transformer

Twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation
Fully shrouded bobbins
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Insulation Class B (130°C)
Isolation (Primary to Secondary) 4 kV rms
Isolation (Windings to core) 2 kV rms
Pin Length x Diameter 5 x 1 mm
Maximum Winding Temperature Rise +55°C
//media.rs-online.com/t_line/L231852-01.gif

Approvals

8888

Standards

BS3535; EN 60 742

Open Frame - Laminated

PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section metric bobbin construction
Full varnish impregnation

Technical specifications
VA regulation dimensions (mm)     pins (mm)   weight
nominal typ. (%) L L h* L Ø (kg)
3 20 38 35 30 5 1 0.14
6 25 43 36 33 5 1 0.18
12 12 54 45 41 5 1 0.4
* above the PCB
Specifications
Attribute Value
Secondary Voltage Rating 24V ac
Power Rating 3VA
Primary Voltage Rating 115 V ac, 230 V ac
Number of Outputs 2
Length 38mm
Width 35mm
Depth 30mm
Dimensions 38 x 35 x 30mm
Weight 140g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
78 In stock for FREE next working day delivery
Price Each
£ 7.37
(exc. VAT)
£ 8.84
(inc. VAT)
Units
Per unit
1 - 9
£7.37
10 - 24
£7.10
25 +
£6.62
Related Products
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz ...
Description:
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not ...
High quality open style toroidal transformers with dual ...
Description:
High quality open style toroidal transformers with dual 115Vac 50/60Hz primary and secondary windings which may be connected in series or parallel or used independently. Small size and low weight compared with traditional stacked lamination typesExtremely low level of radiated magnetic fieldVery low induced noise (hum)Very low iron lossSupplied with ...