Preventa XCS-DMP Magnetic Safety Switch, Plastic, 24 V dc

Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): FR
Product Details

XCS-DMC/XCS-DMP Coded Magnetic Switches, Rectangular

XCS-DM coded magnetic safety switches are designed for monitoring the doors, covers and guards of industrial machines with imprecise guiding and low inertia. These safety switches are ideally suited for machines subjected to frequent washing or liquid spray. They protect the operator by immediately stopping any dangerous movement as soon as the distance between the switch and its magnet is greater than 8mm (5mm for XCS-DMC).
XPS-DM safety modules are specifically designed for monitoring the coded magnetic safety switches. When the XCS-DM safety switch is used in conjunction with the XPS-DM safety relay they offer a certified safety solution for guard monitoring.

Coded magnetic safety switch

Actuation on 3 sides: face to face and face to side
8mm tolerance to misalignment (5mm for XCS-DMC)
LED versions have an LED in series with one N/C giving indication when guard is closed
Coded reed technology - switch cannot be totally defeated by a simple magnet
Rectangular plastic housing
Dimensions: compact: H51 x W16 x D7mm, standard: H88 x W25 x D13mm
Available pre-cabled or with connector on flying lead
IP66/67 protection in accordance with EN/IEC 60529
ROHS compliant

Safety module

Allows multi-switch monitoring to Safety Category 4 solutions in accordance with EN954-1/ISO 13849-1
XPS-DMB can monitor 2 independent sensors and modules, XPS-DME can monitor 6 independent sensors and modules
2 safety outputs and 2 solid state outputs for signalling to the process PLC
LEDs on the front face provide information on the monitoring circuit status
Dimensions: H99 x W22 x D114mm
IP20 protection on terminals and IP40 protection on enclosure, in accordance with EN/IEC 60529

Note

With the appropriate monitoring system and correctly wired these switches can reach safety category 4 conforming to EN/ISO 13849-1, PL e conforming to EN/ISO 13849-1, SIL 3 conforming to EN/IEC 61508.

Standards

IEC 947-1; EN 547-5-1; EN 547-5-3; EN 60204-1; EN 1088 (for Magnetic Switch only)
IEC 204-1; EN 292; EN 60204-1; EN954-1; EN1088 (for Safety Module only)

Specifications
Attribute Value
Supply Voltage 24 V dc
Housing Material Plastic
Range Preventa
Terminal Type Cable
Series XCS-DMP
IP Rating IP66, IP67
Actuator Included Yes
Dimensions 88 x 25 x 13 mm
Number of Approach Directions 3
Sensor Principle Magnetic
Safety Category 4
Actuator Type Coded
Width 25mm
Length 88mm
Depth 13mm
6 In stock for FREE next working day delivery
Price Each
£ 70.00
(exc. VAT)
£ 84.00
(inc. VAT)
Units
Per unit
1 +
£70.00
Related Products
Smallest design Actuation only possible with BPS260, available ...
Description:
Smallest design Actuation only possible with BPS260, available separately Left-hand or right-hand side versions for door-mounting Control category up to 4 to EN954-1IP67 protection Connector 8 mm, 6-pole, latching interlocking Dimensions: L13 x W26 x H36 mm.
Ex coded magnetic safety switches can be used ...
Description:
Ex coded magnetic safety switches can be used in potentially explosive DUSTY or GASEOUS environments for safety applications, for example on machines fitted with small guards or covers (with loose alignment), packaging machines, food and beverage processing (sugar refinery, malt house manufacturers, flour mills), petrochemical plants etc. They are approved ...
Non-contact actuation Magnetic coded sensing High tolerance to ...
Description:
Non-contact actuation Magnetic coded sensing High tolerance to misalignment LED indication2 N/C solid state relay outputs and 1 PNP auxiliary output Switching current: 200 mA @ 24Vdc Supply Voltage: 24Vdc IP 69K protection rating Category 1 device per EN 954-1, dual channel contacts suitable for Cat 3 or 4 systems. ...
Description:
Eden - Adam and Eva from ABB is a non-contact safety sensor for use on interlocked gates, hatches etc. A coded signal is transmitted from the control device Vital or from the safety PLC Pluto via Adam to Eva which modifies the signal and sends it back again. The maximum ...