Broyce Control Phase Monitoring Relay With SPDT Contacts, 400 V ac, 3 Phase

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

45PSR 3-Phase Sequence/Failure Relay

Detects phase loss
Detects incorrect phase sequence
Monitors own supply
LED indication for correct/incorrect phase sequence
DIN Rail housing
Installation/Data sheet supplied

Phase Sequence/Failure Relays

Monitoring of 3 phase supplies
Orange housing manufactured to DIN 43 880
DIN rail mount

Specifications
Attribute Value
Monitoring Application Phase
Supply Voltage 400 V ac
Contact Configuration SPDT
Electrical Phase 3
Phase Sensitivity Phase Loss, Phase Sequence
Time Delay 200 ms
Operating Temperature Range -20 → +60 °C
Minimum Operating Temperature -20°C
Width 45mm
Dimensions 99 x 45 x 78 mm
Length 99mm
Maximum Operating Temperature +60°C
Height 78mm
27 In stock for FREE next working day delivery
Price Each
£ 74.99
(exc. VAT)
£ 89.99
(inc. VAT)
Units
Per unit
1 - 4
£74.99
5 +
£71.94
Related Products
Schneider Electric Zelio RM22UA series single phase or ...
Description:
Schneider Electric Zelio RM22UA series single phase or DC voltage control relays. Automatic AC or DC recognitionSelection between overvoltage and undervoltageMonitoring of their own supply voltage measured as a true rms valueSelectable memory functionLED indication35 mm DIN Rail mount.
Voltage monitoring 3-phase against N, Voltage failure monitoring, ...
Description:
Voltage monitoring 3-phase against N, Voltage failure monitoring, 400V, 2 CO, fixed threshold voltage Us=195,5V. Monitoring relays - ENYA seriesUndervoltage monitoringSupply voltage = measured voltage2 change over contactsWidth 35 mmInstallation designTaskThe emergency lighting is activated in the event of a mains failure or undervoltage.SolutionThe mains failure is monitored with a ...
The IL9079 is an undervoltage relay for detecting ...
Description:
The IL9079 is an undervoltage relay for detecting short interruptions. Enclosure version for the IL 9079 has a depth of 59 mm. Terminals are at the bottom for installation systems and industrial distribution systems according to DIN 43 880. Features & BenefitsDetecting undervoltage, short interruptions or phase loss in 3 ...
Separate relay & LED operation for three phase ...
Description:
Separate relay & LED operation for three phase monitoring 'V' & thermistor monitoring 'T'The relay monitors the following:Incorrect phase sequence/rotationThreshold voltage 60% of 400VacPhase failure/lossPhase under-voltage (0.6 x 400Vac)Thermistor over-temperatureThermistor open circuitThermistor short circuitOutput relay: 10A (thermistor)Output relay: 10A (3 phase).