Broyce Control Current Monitoring Relay With SPDT Contacts, 230 V ac, 1 Phase

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

DIN Style Single Phase Over Current Relay

Multi range
Adjustable hysteresis
Latching facility
Adjustable fault delay
Adjustable start -up delay
Switchable relay inversion
LED indication
Write on ID tab
Dimensions: H78 x W45 x D99mm

//media.rs-online.com/t_line/LD299191-01.gif
//media.rs-online.com/t_line/LE299191-01.gif

Broyce Economical Range

LED indication
DIN rail mount with SPDT relay outputs and flame retardant to UL94 V0
Supply voltage variation range: 0.85 - 1.15 x Un
Operating temperature range: -20 to 60°C (629-831 and 629-847: -10 to +55°C)
Electrical life: 1.5 x 105 operations at rated load

Note

Output relay contact rating specified at 250Vac

Specifications
Attribute Value
Monitoring Application Current
Supply Voltage 230 V ac
Contact Configuration SPDT
Electrical Phase 1
Current Sensitivity Overcurrent
Minimum Current Sensed 5mA
Maximum Current Sensed 1A
Time Delay 0.1 → 3 s
Minimum Operating Temperature -20°C
Dimensions 99 x 45 x 78 mm
Height 78mm
Maximum Operating Temperature +60°C
Operating Temperature Range -20 → +60 °C
Width 45mm
Current Range 0.05 → 1 A, 0.5 → 10 A, 5 → 100 mA
Length 99mm
11 In stock for FREE next working day delivery
Price Each
£ 76.13
(exc. VAT)
£ 91.36
(inc. VAT)
Units
Per unit
1 - 4
£76.13
5 +
£73.05
Related Products
TELE KAPPA series AC current monitoring for single ...
Description:
TELE KAPPA series AC current monitoring for single phase mains. Featuring overcurrent and undercurrent monitoring and a single change over contact. The KAPPA series have a self-extinguishing plastic body with an IP rating of IP40 and a DIN-rail TS 35 mounting. Shock resistant DIN Rail mount LED indicator Screw terminals ...
Detects Over frequency OFR relay energises if frequency ...
Description:
Detects Over frequency OFR relay energises if frequency rises above trip level – red LED off, contacts 11, 12 /21 & 22Adjustable trip level: 40 → 60Hz Adjustable hysteresis Monitors own supply1 x DPDT relay output: 8ALED indication for supply and relay status DIN rail housing Write on identification tab ...
Detects over-current condition Adjustment for trip level Monitors ...
Description:
Detects over-current condition Adjustment for trip level Monitors current in 3-phase supply Time delay (from fault) with adjustable setting: 0.2 to 10s1 x DPDT relay output 8ALED indication for supply and relay status DIN rail or surface mount Dimensions: H70 x W100 x D112mm.
For monitoring the power consumption of electrical loads. ...
Description: