Broyce Control Phase Monitoring Relay With SPDT Contacts, 400 V ac Supply Voltage, 3 Phase

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

DIN Style Phase Asymmetry Relay

The relay monitors:

Presence of supply
Correct rotation
Correct phase angle
Dimensions: H78 x W45 x D99mm

//media.rs-online.com/t_line/LE299190-01.gif

Broyce Economical Range

LED indication
DIN rail mount with SPDT relay outputs and flame retardant to UL94 V0
Supply voltage variation range: 0.85 - 1.15 x Un
Operating temperature range: -20 to 60°C (629-831 and 629-847: -10 to +55°C)
Electrical life: 1.5 x 105 operations at rated load

Note

Output relay contact rating specified at 250Vac

Specifications
Attribute Value
Monitoring Application Phase
Supply Voltage 400 V ac
Contact Configuration SPDT
Electrical Phase 3
Phase Sensitivity Phase Asymmetry, Phase Loss, Phase Sequence
Time Delay 200 ms
Height 78mm
Maximum Operating Temperature +60°C
Operating Temperature Range -20 → +60 °C
Width 45mm
Length 99mm
Dimensions 99 x 45 x 78 mm
Minimum Operating Temperature -20°C
4 In stock for FREE next working day delivery
Price Each
£ 63.46
(exc. VAT)
£ 76.15
(inc. VAT)
Units
Per unit
1 - 4
£63.46
5 +
£60.87
Related Products
Broyce Controls L-Series signal conditioners use a QR ...
Description:
Broyce Controls L-Series signal conditioners use a QR barcode marking method allowing direct access to all technical data sheets, ensuring correct information is always at your finger tips! Compact 17.5 mm DIN Rail housing Microprocessor based True R.M.S. monitoring measuring phase to phase (three wire) or phase to neutral (4-wire) ...
Voltage monitoring 3-phase against N, Voltage failure monitoring, ...
Description:
Voltage monitoring 3-phase against N, Voltage failure monitoring, 400V, 2 CO, fixed threshold voltage Us=195,5V. Monitoring relays - ENYA series Undervoltage monitoring Supply voltage = measured voltage2 change over contacts Width 35 mm Installation design TaskThe emergency lighting is activated in the event of a mains failure or undervoltage.Solution The ...
Separate relay & LED operation for three phase ...
Description:
Separate relay & LED operation for three phase monitoring 'V' & thermistor monitoring 'T'The relay monitors the following:Incorrect phase sequence/rotation Threshold voltage 60% of 400Vac Phase failure/loss Phase under-voltage (0.6 x 400Vac)Thermistor over-temperature Thermistor open circuit Thermistor short circuit Output relay: 10A (thermistor)Output relay: 10A (3 phase).
Detects over-current condition Adjustment for trip level Monitors ...
Description:
Detects over-current condition Adjustment for trip level Monitors current in 3-phase supply Time delay (from fault) with adjustable setting: 0.2 to 10s1 x DPDT relay output 8ALED indication for supply and relay status DIN rail or surface mount Dimensions: H70 x W100 x D112mm.