Broyce Control Speed Monitoring Relay With SPDT Contacts, 230 V ac

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

45175 Underspeed Relay

Monitoring input: Pulse from NPN open collector proximity switch or volt-free contact

Additional features:

LED indication
Adjustable time delay
Latching facility
Write on ID tab
Dimensions: H78 x W45 x D99mm

//media.rs-online.com/t_line/LD298941-01.gif

Broyce Economical Range

LED indication
DIN rail mount with SPDT relay outputs and flame retardant to UL94 V0
Supply voltage variation range: 0.85 - 1.15 x Un
Operating temperature range: -20 to 60°C (629-831 and 629-847: -10 to +55°C)
Electrical life: 1.5 x 105 operations at rated load

Note

Output relay contact rating specified at 250Vac

Specifications
Attribute Value
Monitoring Application Speed
Supply Voltage 230 V ac
Contact Configuration SPDT
Time Delay 0.5 → 30 min, 0.5 → 30 s
Minimum Operating Temperature -20°C
Maximum Operating Temperature +60°C
Height 78mm
Dimensions 99 x 45 x 78 mm
Length 99mm
Width 45mm
Operating Temperature Range -20 → +60 °C
56 In stock for FREE next working day delivery
Price Each
£ 63.46
(exc. VAT)
£ 76.15
(inc. VAT)
Units
Per unit
1 - 4
£63.46
5 +
£60.87
Related Products
DIN standard case, which may be front panel ...
Description:
DIN standard case, which may be front panel or chassis mounted (11-pin socket 403-869). Monitors the speed of machinery via the inputs from RS inductive proximity switches, open collector transistor or relay contact type devicesOn-board 24V dc supply for proximity device and an output suitable to drive a 100μA FSD ...
TELE KAPPA series AC current monitoring for single ...
Description:
TELE KAPPA series AC current monitoring for single phase mains. Featuring overcurrent and undercurrent monitoring and a single change over contact. The KAPPA series have a self-extinguishing plastic body with an IP rating of IP40 and a DIN-rail TS 35 mounting. Shock resistantDIN Rail mountLED indicatorScrew terminalsMultifunction2 change over contacts38 ...
No external sensors necessaryIndependent of directionBroken wire detectionForcibly ...
Description:
No external sensors necessaryIndependent of directionBroken wire detectionForcibly guided safety contacts:3 NO contacts, 1 NC contact for AC 250 V2 semiconductor monitoring outputs1 monitoring output (NO contact)Adjustable voltage settingAdjustable standstill time delayLED indicators for standstill, event of line breakage and operation voltageSuitable for operation with invertersWidth 45 mmAdvantages / Customer ...
Safe standstill detection on 3and single-phase motorsNo external ...
Description:
Safe standstill detection on 3and single-phase motorsNo external sensors necessaryIndependent of directionBroken wire detectionForcibly guided safety contacts:3 NO contacts, 1 NC contact for AC 250 V2 semiconductor monitoring outputs1 monitoring output (NO contact)Adjustable voltage settingAdjustable standstill time delayLED indicators for standstill, event of line breakage and operation voltageSuitable for operation ...