Product Details

GAMMA Series Power Factor Monitoring Relay

TELE GAMMA series single and three phase power factor monitoring relay. Multifunction monitoring in a slim easy to use package. The GAMMA series have a self-extinguishing plastic body with an IP rating of IP40.

Monitoring of inductive and capacitive consumers (up to 19.6kW)
Multifunction
Temperature monitoring of the motor winding
Reset-key, Fault latch
Suitable for VFI (10 to 100Hz)
2 change over contacts
Width 45mm
Screw terminals

Telecontrol GAMMA Monitoring Relays

Specifications
Attribute Value
Monitoring Application Power, Temperature
Supply Voltage 12 → 500 V ac
Contact Configuration DPDT
Electrical Phase 1, 3
Voltage Sensing Range 3 → 690 V
Minimum Current Sensed 8A
Maximum Current Sensed 16A
Time Delay 1 → 50 (Tripping) s, 3 → 180 (Start Up) s
Maximum Voltage Sensed 690V
Mounting Type DIN Rail
Series GAMMA
Standards Met EN 60715, IEC 60068-2-27, IEC 60664-1, IEC 60668-2-6, IEC 60721-3-3, IEC 60947-5-1, UL 508
Maximum Operating Temperature +55°C
Dimensions 45 x 108 x 90 mm
Height 90mm
Terminal Type Screw
Operating Temperature Range -25 → +55 °C
Number of Poles 2
Minimum Voltage Sensed 3 V
Width 108mm
Length 45mm
Minimum Operating Temperature -25°C
Current Range 8 → 16 A
21 In stock for FREE next working day delivery
Price Each
£ 268.12
(exc. VAT)
£ 321.74
(inc. VAT)
Units
Per unit
1 +
£268.12
Related Products
3 phase network control relay protects motors and ...
Description:
3 phase network control relay protects motors and equipment from expensive damage due to voltage faults on 3 phase systems. It monitors the sequence of phases L1, L2, L3 and failure of one or more phases. This 3 phrase control relay can be used in applications such as heating/air conditioning, ...
Thermistor motor protection relay Standard evaluation unit 22.5 ...
Description:
Thermistor motor protection relay Standard evaluation unit 22.5 mm enclosure Spring-type terminal 2 change-over contacts US = 24 V AC/DC Manual/Auto/Remote reset with ATEX approval 2 LEDs (READY/TRIPPED) galvanic isolation Test/reset button Wire break monitoring Short circuit monitoring non-volatile.
Voltage monitoring 3-phase against N, Voltage failure monitoring, ...
Description:
Voltage monitoring 3-phase against N, Voltage failure monitoring, 400V, 2 CO, fixed threshold voltage Us=195,5V. Monitoring relays - ENYA series Undervoltage monitoring Supply voltage = measured voltage2 change over contacts Width 35 mm Installation design TaskThe emergency lighting is activated in the event of a mains failure or undervoltage.Solution The ...
Voltage monitoring 1- or 3-phase, Multifunction, monitoring of ...
Description:
Voltage monitoring 1- or 3-phase, Multifunction, monitoring of over- and under-voltage, monitoring of phase sequence selectable, 2 CO, Adjustable delay. Monitoring relays - ENYA series MultifunctionMonitoring of phase failure Monitoring of phase sequence selectable Connection of neutral wire optional2 change over contacts Width 35 mm Installation design.