Tele Liquid Level Monitoring Relay With SPDT Contacts, 230 V ac Supply Voltage, 1 Phase

  • RS Stock No. 123-9720
  • Mfr. Part No. E3LM10 230V AC
  • Brand Tele
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): AT
Product Details

ENYA Series Level Monitoring Relay

TELE ENYA series level control monitoring relay for conductive liquids. Featuring pump up and pump down monitoring and a single change over contact. The ENYA series have a self-extinguishing plastic body with an IP rating of IP40.

DIN Rail mount
LED indicator
Screw terminals
Multifunction
Secure isolation of the measuring circuit
1 change over contact
17.5 mm width

Specifications
Attribute Value
Monitoring Application Liquid Level
Supply Voltage 230 V ac
Contact Configuration SPDT
Electrical Phase 1
Time Delay 0.5 → 10 s
Minimum Operating Temperature -25°C
Length 35mm
Width 65mm
Number of Poles 1
Operating Temperature Range -25 → +55 °C
Terminal Type Screw
Mounting Type DIN Rail
Standards Met EN 60715, IEC 60664-1, IEC 60668-1, IEC 60721-3-3, IEC 60947-5-1
Maximum Operating Temperature +55°C
Dimensions 35 x 65 x 87 mm
Height 87mm
Series ENYA
11 In stock - FREE next working day delivery available
Price Each
£ 81.38
(exc. VAT)
£ 97.66
(inc. VAT)
Units
Per unit
1 - 4
£81.38
5 - 9
£78.94
10 +
£76.50
Related Products
Broyce Controls L-Series signal conditioners use a QR ...
Description:
Broyce Controls L-Series signal conditioners use a QR barcode marking method allowing direct access to all technical data sheets, ensuring correct information is always at your finger tips! Compact 17.5 mm DIN Rail housing Microprocessor based True R.M.S. monitoring Selectable nominal voltages to suit most popular single phase supply voltages ...
For AC and DC systems Type BTo detect ...
Description:
For AC and DC systems Type BTo detect earth faults in grounded voltage systems4 setting ranges from 10 mA to 3 AManual reset, with alarm and pre-warning With adjustable switching delay Energized or de-energized on trip LED indicator for operation, pre-alarm and alarm With test function LED-chain indicates fault current ...
Detection of undervoltage in 3-phase systems Without separately ...
Description:
Detection of undervoltage in 3-phase systems Without separately auxiliary voltage (internal supply from all 3 phases)LED indication for operation voltage and contact position De-energised on trip RK 9871.71: 1 changeover contact RK 9871.72: 2 changeover contacts With fixed time delay of 0.5s for fault indication With fixed time delay of ...
Detects Over frequency OFR relay energises if frequency ...
Description:
Detects Over frequency OFR relay energises if frequency rises above trip level – red LED off, contacts 11, 12 /21 & 22Adjustable trip level: 40 → 60Hz Adjustable hysteresis Monitors own supply1 x DPDT relay output: 8ALED indication for supply and relay status DIN rail housing Write on identification tab ...