Allen Bradley 800F-PX01S Contact Block, For Use With 800F Series

Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
Product Details

800 FM Series, Self-Monitoring Contact Block

Self Monitoring N/O contact automatically closes when the contact block is correctly installed on the operator, in this condition the emergency stop N/C contact operates conventionally. If the contact block should come detached from the emergency stop body the Self Monitoring contact will open ensuring fail safe operation of the emergency stop
Can be used as part of emergency stop safety relay circuit
Fine silver electrical contacts for improved continuity
Low voltage low current switching: Max current; 3A @ 240Vac and 0.55A @ 125Vdc
Pre-assembled complete with latch
IP2X finger safe protection

Emergency Stop Pushbutton

Specifications
Attribute Value
Accessory Type Contact Block
For Use With 800F Series
22 In stock for FREE next working day delivery
Price Each
£ 7.94
(exc. VAT)
£ 9.53
(inc. VAT)
Units
Per unit
1 +
£7.94
Related Products
Our Bulletin 440F Safedge™ Safety Edge Profiles come ...
Description:
Our Bulletin 440F Safedge™ Safety Edge Profiles come in three different cushion factors and two different materials. They have no rigid internal parts that can break through or cause fatigue failures after prolonged use. Various profiles availableConductive rubber technologyUp to 50 m lengthsAluminum, plastic or zinc-coated steel mounting railsRubber boot ...
Our Bulletin 800Z Zero-Force Touch Buttons™ are designed ...
Description:
Our Bulletin 800Z Zero-Force Touch Buttons™ are designed for machine control systems that require the use of two hands. An interlinked sensor surface weaves two capacitive sensors in offset planes for superior product sensitivity. When you touch the surface of the switch, you initiate an output. Our buttons can detect ...
Ideally suited to replacing traditional tongue interlocks - ...
Description:
Ideally suited to replacing traditional tongue interlocks - same footprint as Trojan tongue interlock.In applications where excessive force can be generated eg rebound of heavy doors, the TLS-GD2 or Atlas should be considered. Supplied with dedicated Spartan actuatorPower to releaseLid mounted status indication2N/C 1N/O contactsRotatable head: 4 possible actuator entry ...
Pre-cabled, contact-free locking safety switches that provide performance ...
Description:
Pre-cabled, contact-free locking safety switches that provide performance equal or superior to that offered by mechanical locking devices.These switches are fully sealed to IP67, for applications requiring strict hygiene.Two switches are available: type 1 in a small housing, and type 2 in a longer housing.The circuit opens when the magnet ...