Carlo Gavazzi Level Sensor PNP Output

Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): DK
Product Details

Capacitive Level Sensor

CE marked in compliance with relevant European Directives

Sensing range 2 to 10mm adjustable via a single turn potentiometer
LED indication when activated
Output: DC 100mA transistor
Power ON delay; Max 40ms (No delay version), Max 5s (ON/OFF delay versions)
Supply voltage; 5-30Vdc
No load current; ≤10mA
Operating temperature range 0 to + 50°C
Housing material; grey ABS and polycarbonate
Ingress protection to IP65
1.5 m, 3 x 0.3mm2 PVC cable

Approvals

UL

Approvals

UL

Specifications
Attribute Value
Device Type Capacitance
Switch Output PNP
Body Material ABS, Polycarbonate
Cable Length 1.5m
Minimum Operating Temperature 0°C
Maximum Operating Temperature +50°C
Maximum DC Voltage 30V
Maximum Current 100 mA
3 In stock for FREE next working day delivery
Price Each
£ 44.58
(exc. VAT)
£ 53.50
(inc. VAT)
Units
Per unit
1 - 4
£44.58
5 - 9
£43.20
10 +
£41.82
Related Products
Sensor and signal processor in one stainless steel ...
Description:
Sensor and signal processor in one stainless steel compact housing On-delay time: 8s (typical)Ingress protection to IP67Simple adjustment via LED bar graph and potentiometer Response time: 12s max.Switch on and off times: 2s typical Output - PNP transistor; short-circuit proof; reverse polarity protected Fluid temperature range: –25 to +80°C (100°C ...
Fill level monitoring by means of guided microwaves ...
Description:
Fill level monitoring by means of guided microwaves Updated display of the current fill level Programmable hysteresis and window function Simple operation via the user menu The length of the sensor probe can be shortened as desired Available probes 228 mm (RS order no. 488-047) or 688 mm (RS order ...
The LFV200 product family of universal vibrating level ...
Description:
The LFV200 product family of universal vibrating level switches precisely detects predefined liquid levels in systems to the millimeter. The switches can emit a signal to prevent overfilling, a switching signal for refilling, or a dry-run signal for pump protection. The LFV200 works independently of the liquid and is wear-free ...
A single pole electrode used for level control ...
Description:
A single pole electrode used for level control in wells or storage tanks. It comprises stainless steel probe with plastic holder and cable gland. A seal ring and the tightening of the cable gland prevent liquid from entering the cable terminal connector and causing its oxidation. Maximum operating temperature -10°C ...