2P Impulse Relay With 2NO Contacts, 16 A, 12 V dc, 24 V ac Coil

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): BE
Product Details

Acti9 iTL Impulse Relays

iTL impulse relays are used to control by pushbuttons lighting circuits consisting of incandescent lamps, low-voltage halogen lamps, fluorescent lamps and discharge lamps.

Closing of the impulse relay pole is triggered by an impulse on the coil
Having two stable mechanical positions, the pole will be opened by the next impulse
Can be controlled by an unlimited number of pushbuttons.
Zero energy consumption

Specifications
Attribute Value
Number of Poles 2
Range Acti 9
Coil Voltage 12 V dc, 24 V ac
Switching Voltage 12 V dc, 24 V ac
Switching Current 16 A
Terminal Type Through Hole
Contact Configuration 2NO
Mounting Type DIN Rail
Series iTL
6 In stock - FREE next working day delivery available
Price Each
£ 51.00
(exc. VAT)
£ 61.20
(inc. VAT)
Units
Per unit
1 - 9
£51.00
10 - 14
£47.93
15 +
£45.90
Related Products
TELE GAMMA series AC/DC current monitoring for single ...
Description:
TELE GAMMA series AC/DC current monitoring for single phase. Featuring overcurrent and undercurrent monitoring and two change over contacts. The GAMMA series have a self-extinguishing plastic body with an IP rating of IP40. DIN Rail mount LED indicator Screw terminals Multifunction16.6 to 400Hz Fault latch2 change over contacts.
Digital adjustable multifunction timer Functions can be adjusted ...
Description:
Digital adjustable multifunction timer Functions can be adjusted separately for each output relay Off (OFF)Instantaneous contact (ON)On-delay (AV)Fleeting on make (EW)Delayed pulse with adjustable pulse length (IE)Cyclic timer, start with impulse (TI)Cyclic timer, start with break (TP)Off-delay (RV)Pulse forming function (IF)Fleeting on break (AW)Fleeting on make and break (EW / ...
Thermistor motor protection relay with and without ATEX ...
Description:
Thermistor motor protection relay with and without ATEX approval For detection of- Temperature limit exceedance- Wire breakage in sensor circuit- Short circuit in sensor circuit (ATEX version). 1 input for 1 → 6 thermistors Closed circuit current principle (output relay not activated in the event of a fault)LED indicator for ...
Special relay for alternating loads. Suitable for applications ...
Description:
Special relay for alternating loads. Suitable for applications with pumps, compressors, air conditioning or refrigeration units. 2 independent NO output, 12 A2 independent control signals, insulated from supply Modular housing, 35 mm wide4 functions Cadmium free contact material.