RS Pro Single Core Harsh Environment Wire, 14 AWG 100m, 600 V, Tinned Copper 37 Strands

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

ETFE (Tefzel) Wires

This ethylene tetrafluoroethylene (also known as Tefzel) insulated wire in manufactured to meet the requirements of defence standard 61-12 Part29/1. Its outer sheath resists temperatures up to +270 °C and has good chemical and abrasion resistance. The wire conductors are made from tin plated copper wire. The properties of ethylene tetrafluoroethylene wire make it suitable for use in a wide variety of industries and applications including, aerospace, nuclear cables, electronics wiring, medical wiring and appliance wiring.

Features and Benefits

•Flame retardant
•Thin and lightweight
•Resistant to abrasion, fuel, oil and chemicals
•Available in black or white
•Defence standard 61-12 Part29/1 compliant

Tensile strength N/mm2 45 Conductor (a.w.g.) Max. mass (kg/km) Max. wire resistance (Ω/km @ 20°C) Max. cable resistance (Ω/km @ 20°C)
Elongation % 200 24 3.44 94.80 98.60
Hardness D75 22 4.89 61.30 63.70
Water absorption 20°C % 0.03 20 7.73 33.60 35.00
Density g/cm3 1.7 18 11.78 21.20 22.10
Dielectric constant 2.6 16 16.10 14.60 15.20
Dissipation factor 106Hz 0.005 14 21.50 10.70 11.10
Radiation resistance (RADS) 2x10 8 12 33.70 6.44 6.70
Oxygen index 30        
Conductor (AWG) Conductor Strands (mm) Cable O/D (mm) Max. mass (kg/km) Max. wire resistance (Ω/km @ 20°C) Max. cable resistance (Ω/km @ 20°C)
24 19 / 0.12 2 3.44 94.80 98.60
22 19 / 0.15 2.15 4.89 61.30 63.70
20 19 / 0.2 2.4 7.73 33.60 35.00
18 19 / 0.25 2.85 11.78 21.20 22.10
16 19 / 0.30 3.1 16.10 14.60 15.20
14 37 / 0.25 3.41 21.50 10.70 11.10
12 37 / 0.32 3.94 33.70 6.44 6.70

Note

The maximum working voltage on these cables is 600Vac

Standards

DEF STAN 61-12 Part 29/1

Standards

Defence Standard 61 - 12 Part 29 / 1

Specifications
Attribute Value
Sheath Colour Black
American Wire Gauge 14
Insulation Material ETFE
Core Strands 37/0.25 mm
Minimum Operating Temperature -40°C
Maximum Operating Temperature +135°C
Operating Temperature Range -40 → +135 °C
Length 100m
Outer Diameter 2.46mm
Voltage Rating 600 V
Conductor Material Tinned Copper
Size of Strands 0.25 mm
Cable Shape Single Core
Number of Strands 37
Insulation Wall Thickness 0.3mm
Discontinued product