Block 4000VA Isolating Transformer, 230V ac Primary 1 x, 115V ac, 230V ac Secondary

  • RS Stock No. 738-7969
  • Mfr. Part No. TTMS 4000/230
  • Brand Block
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

TTMS Series Medical Transformers

The TTMS series of isolation transformers have a rated input of 230 V ac and a rated output voltage of 115 V ac and 230 V ac. These isolation transformers are protected from overload by a PTC resistor that is integrated in every coil to set up an external monitoring unit. Reduced starting currents enable excellent switch-on behaviour and these isolation transformers feature low short circuit voltage and very low idle current. BLOCKIMPEX vacuum impregnation allows for low noise and excellent corrosion protection. With a robust metal fixing rail featuring 8 oval slots, these isolation transformers are easy to mount.

Features & Benefits

Safe galvanic isolation
IP00 protection
97% efficient
Insulation class B
UVV BGV A3 compliant contact protected screw terminals
+40°C maximum ambient temperature

Product Application Information

These isolation transformers have been designed for supplying user group 2 medical rooms.

Brand Information

BLOCK is a global leader in power supply interface. Developing and producing switched mode power supplies through to coiled goods, BLOCK also offer cast resin optimisation and software development.

Laminated

Specifications
Attribute Value
Primary Voltage Rating 230V ac
Secondary Voltage Rating 115V ac, 230V ac
Power Rating 4000VA
Number of Outputs 1
Length 310mm
Width 190mm
Depth 395mm
Dimensions 310 x 190 x 395mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Maximum Temperature +40°C
Weight 55kg
1 In stock for FREE next working day delivery
Price Each
£ 622.31
(exc. VAT)
£ 746.77
(inc. VAT)
Units
Per unit
1 +
£622.31
Related Products
Brought to you by Block, this range of ...
Description:
Brought to you by Block, this range of Safety Isolating Transformers are short-circuit proof and feature thermal overload protection. The single phase transformers are provided with mounting holes for easy installation, and have two independent secondary windings, which may be connected in series or parallel. These highly efficient safety isolating ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not ...
Single and twin secondary windings for series or ...
Description:
Single and twin secondary windings for series or parallel connectionVacuum resin moulded to UL94-V0 ratingLow inter-winding capacitanceLow radiated noise100% electrical and flash testedExtra fixing points for secure board mounting (25 VA and 36 VA).
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connectionTwin secondary windings for series or parallel connectionLow profile compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedLow inter-winding capacitanceLow radiated noiseExtra fixing holes for secure board mountingStandard: EN60742, VDE ...