XP Power 48W Power Brick AC/DC Adapter 12V dc Output, 4A Output

Unavailable
RS will no longer stock this product.

Alternative

This product is not currently available. Here is our alternative recommendation.

Each

£45.36

(exc. VAT)

£54.43

(inc. VAT)

RS Stock No.:
121-7027
Mfr. Part No.:
AFM45US12
Brand:
XP Power
Find similar products by selecting one or more attributes.
Select all

Brand

XP Power

Adapter Type

Power Brick Adapter

Output Voltage

12V dc

Input Voltage

80 → 264V ac

Output Current

4A

Maximum Temperature

+60°C

Output Connector

DC Plug

Input Connector

IEC 320-C14

Number of Outputs

1

Power Rating

48W

Cable Length

950mm

Medical Approved

Yes

MTBF

>250kh

Standards Met

CCC Qualified, CEC2008, EISA2007, EN 55011/22/FCC, EN 60601-1, EN 60601-1-2, EN 60950-1, EN 61000-3-2, EN 61000-3-3, EN 61000-4-11, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, IEC 60601-1, IEC 60950-1, MIL-HDBK-217F, UL 60601-1, UL 60950-1

Line Regulation Range

±1%

Length

121mm

Load Regulation

2.5%

Series

AFM

Minimum Temperature

0°C

Width

50mm

Depth

30.8mm

Energy Efficiency Level

V

COO (Country of Origin):
CN

XP Power Desktop Power Supply


The XP Power AFM series plug-in Power unit desktop Power supply has an output voltage rating of 12VDC. It provides 48W of continuous output power in a high-quality, compact enclosure suitable for many general Power applications. It has an input frequency range from 50Hz to 60Hz. While the input voltage rating ranging from 80VAC to 264VAC, its maximum output current is 4A. It is ideal for many small electrical devices.

Features and Benefits


Energy efficiency level V
Output connection type is DC plug
Load regulation range is 2.5%
Holdup time is 8ms
Efficiency is 87.7%

Certifications


CEC2008
EISA2007
IT and medical approvals
China compulsory certification (CCC) qualified
OPTIONAL class II versions
Optional white case versions
EN55011/22/FCC class B conducted
EN55011/22/FCC class B radiated
EN61000-3-2, class A
EN61000-3-3
EN61000-4-2
EN61000-4-3, 3 V/m perf criteria A
EN61000-4-4, level 3 perf criteria A
EN61000-4-5
Installation class 3 perf criteria A
EN61000-4-6, 3 Vrms perf criteria A
EN61000-4-8, 3 A/m, perf criteria A
EN61000-4-11
UL60950-1
IEC60950-1
EN60601-1 (3rd Ed.)
UL60601-1 (2nd Ed.)
IEC60601-1