Fluke i6000s FLEX-36 Current Probe & Clamp, With UKAS Calibration

  • RS Stock No. 912-0024
  • Mfr. Part No. i6000s FLEX-36
  • Brand Fluke
Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): CN
Product Details

Fluke Current Probe & Clamp

The Fluke flex AC current probe is a 36in state of the art device used to measure 6000A. Probes can be used with oscilloscopes, digital multimeters, recorders, or data loggers. The flexible measuring head allows current measurements on conductors that are hard to reach or inaccessible using typical clamp-on current probes. The probes provide a low-voltage (3VAC) output that is proportional to the current being measured.

Features and Benefits

Flexible
Accuracy of ±1 %
Lightweight
Head cable length is 915mm (double insulated)
Head bend radius is 38.1mm
Frequency range is from 10Hz to 50kHz (-3 dB)

Certifications

EN 61010-1: 2001
EN 61010-2-032: 2002
EN 61010-031: 2002
600V rms category III, pollution degree 2
EN 61326 : 1998 +A1, A2, and A3
CAT III 600V

Specifications
Attribute Value
Probe Type AC
Calibrated UKAS
Safety Category CAT III 600 V
Safety Category Level CAT III
Model Number p I6000S FLEX
Best Accuracy ±1 %
Safety Category Voltage 600V
Bandwidth 10 Hz → 50 kHz
1 In stock for delivery within 2 working days
Price Each
£ 706.00
(exc. VAT)
£ 847.20
(inc. VAT)
Units
Per unit
1 +
£706.00
Not available for guaranteed pre 9am/10am delivery
Related Products
Dual range a.c. current clamp nominal measuring ranges ...
Description:
Dual range a.c. current clamp nominal measuring ranges 0.1A to 20A a.c. and 0.5A to 200A a.c.Safe, non intrusive current measurement40Hz to 10k Hz bandwidth Ergonomic jaw design for measurement where access is difficult and allows 'hooking' onto the cable Max. conductor size 20mm dia. or 20 x 5mm bus ...
The i30 may be used in conjunction with ...
Description:
The i30 may be used in conjunction with bench and portable oscilloscopes for accurate non-intrusive ac & dc current measurement.,Applications include: inverters, switch mode power supplies, industrial controllers, automotive leakage currents and other applications requiring accurate isolated current measurement. Hall effect sensing of a.c. and d.c. current Power LED warns ...
Suitable for use with oscilloscopes, recorders and data ...
Description:
Suitable for use with oscilloscopes, recorders and data loggers a.c. coupled output (no d.c. offset) Voltage output of 3V full scale for each range Fits around conductors up to 160mm diameter Extended battery life and external power supply input Meets BS EN61010 – 1 Cat III 600V Extended working temperature ...
Flexible and lightweight a.c. coupled output (no d.c. ...
Description:
Flexible and lightweight a.c. coupled output (no d.c. offset) 3 selectable ranges up to 2000A a.c. Fits around conductors up to 178 mm diameter Voltage output of 2V full scale for each range Suitable for use with multimeters, recorders and data loggers Plugs directly into instruments with 4mm input sockets ...