RS Components
Our website uses cookies and similar technologies to provide you with a better service while searching or placing an order, for analytical purposes and to personalise our advertising to you.
 
MPN

Druck UNO-38023-3275 Current Loop Calibrator Over Boot, For Use With UPS III Loop Calibrator


Available to back order for despatch 05/01/2021
Add to Basket

Price Each

£46.00

(exc. VAT)

£55.20

(inc. VAT)

Units

Added

RS Stock No.:
434-7016
Mfr. Part No.:
UNO-38023-3275
Brand:
Druck

RoHS Status: Not Applicable

COO (Country of Origin):
GB
UnitsPer unit
1 +£46.00

Druck Loop Calibrator - UPS III


Small but mighty, Druck's UPS III loop calibrator offers maximum results with a compact design. The calibrator forms part of an essential toolbox that one may need for calibration and troubleshooting, instrument maintenance and valve set-up. Druck's loop calibrator offers a wealth of time-saving features, all made possible through the advanced microprocessor-based electronics and large menu-driven graphics display.


Features & Benefits


• HART compatible with internal loop resistor
• Weighing just 275g (9.7 oz), and it's dimensional measurements are L129 x W77 x D24 mm - fitting comfortably in a shirt pocket
• Rugged, hardwearing and compact design
• The graphic display with a menu-driven interface has been designed to be super user-friendly
• The internal 0 to 24 V (volts) loop supply is available in both measure and source modes, this is essential during plant shutdowns
• Step, span check and value check can be easily carried out through linearity tests and zero/span adjustments
• The calibrator offers single-handed loop testing, valve set-up and slow rate checks through adjustable rates (1-599 secs)
• The continuity and switch test facility reduce DMM dependence when fault finding, checking loop integrity and testing switches
• Adjustable display contrast and resolution
• Battery voltage and low battery indicator
• The primary reading is shown in mA (milliamp) or %, as linear or square root (flow)
• Auto switch off can be enabled or disabled, when the auto power down is enabled it will power down 30 minutes ager the last key was pressed
• The measurement generation of 0 - 24mA DC
• Predefined values for quick testing of linear loops, flow loops and the control of valves
• Has an operating temperature of 14°F to 122°F (-10°C to 50°C)
• The power supply of this loop calibrator is through 4 x 1.5 V (volts) AA size alkaline batteries
• Electrical terminals are gold plated, 4 mm sockets


Looking for some accessories?


• A universal mains input adapter as an alternative power for the UPS III – 434-7038
• Carry case – 434-7022
• Protective nitrile rubber over-boot, ensuring an extra layer of protection for the device – 434-7016


What's included with the kit?


• A handy user manual
• Set of cables/wires
• Batteries - 4 x 1.5 V AA alkaline
• Calibration certificate as standard


AttributeValue
Accessory TypeOver Boot
For Use WithUPS III Loop Calibrator