Allen Bradley Overload Relay NO/NC, 0.16 → 0.25 A, 250 mA, 7 W, 690 V ac

Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): CN
Product Details

193-K Miniature Bi-metallic Overload Relay

Protects motor against overload and phase loss
Trip class 10
Auxiliary switch 1N/O and 1N/C
Stable, shock-resistant direct mounting on 100-K contactor
Built in trip contact 95//96 and signal contact 97//98
Auto/manual reset selectable on device
visible trip indication
Test/trip actuator
Stop actuator

Specifications
Attribute Value
FLC Motor Rating 0.16 → 0.25 A
Control Voltage 690 V ac
Contact Current Rating 250 mA
Range Bulletin
Contact Voltage Rating 690 V ac
Series 193-K
Normal State Configuration NO/NC
Number Of Auxiliary Contacts 2
Power Rating 7 W
Terminal Type Screw
Reset Method Automatic, Manual
Width 44.9mm
Length 50mm
Depth 78.7mm
Maximum Operating Temperature +60°C
Minimum Operating Temperature -20°C
Operating Temperature Range -20 → +60 °C
1 In stock for FREE next working day delivery
Price Each
£ 24.90
(exc. VAT)
£ 29.88
(inc. VAT)
Units
Per unit
1 - 9
£24.90
10 - 14
£23.40
15 +
£22.41
Related Products
Phase failure sensitive Test Button Trip-Fault Indication Manual ...
Description:
Phase failure sensitive Test Button Trip-Fault Indication Manual or automatic reset facility Temp. compensated trip -20 to +55°C.
The 3RU21 thermal overload relays up to 80 ...
Description:
The 3RU21 thermal overload relays up to 80 A have been designed for current-sensitive protection of loads with normal starting.These thermal overload relays for use with Sirius Size S0 & S00 Contactors. Switch position indicator and test function STOP button Selector switch for manual/automatic reset Screw connection or Spring-clamp versions ...
Type RF38, phase failure sensitive, manual or automatic ...
Description:
Type RF38, phase failure sensitive, manual or automatic resetting Type RFN38, non phase failure sensitive, manual or automatic resetting Type RF82 and RF95, phase failure sensitive, manual resetting Type RFA82 and RFA95, phase failure sensitive, automatic resetting Type RFN82 and RFN95, non phase failure sensitive, manual resetting Type RFNA82 and ...
The solid-state design of the 193-E1 Plus overload ...
Description:
The solid-state design of the 193-E1 Plus overload relay provides accurate, reliable and repeatable protection. A wide 5:1 adjustment range, dip switch (on EE versions) and isolated contacts provide application flexibility. The line-side over moulded power connections provides a sturdy two component starter assembly. The patented modular design allows for ...