RS PRO 150VA 2 Output Chassis Mounting Transformer, 18V ac

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): PL
Product Details

Chassis Mount Frame 75VA to 200VA

The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Optional terminal shrouds for 75VA and 100VA(503-928)

Approvals

8888

Standards

BS3535; EN 60 742

Laminated Frame 230Vac Primary 75VA to 200VA (Multi Tapped)

Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding.

Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Multi-hole frame fixing
Solder tag terminations
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Specifications
Attribute Value
Primary Voltage Rating 230V ac
Secondary Voltage Rating 18V ac
Power Rating 150VA
Number of Outputs 2
Mounting Type Chassis
Length 100mm
Width 82mm
Depth 82mm
Dimensions 100 x 82 x 82mm
Fixing Hole Diameter 5.5 x 8.5mm
Weight 2kg
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
10 In stock for FREE next working day delivery
Price Each
£ 31.91
(exc. VAT)
£ 38.29
(inc. VAT)
Units
Per unit
1 - 24
£31.91
25 +
£28.74
Related Products
Multi-tapped secondary winding. Suitable for a wide range ...
Description:
Multi-tapped secondary winding. Suitable for a wide range of applications requiring selected secondary voltages. Double section bobbin construction Fully shrouded bobbins Full varnish impregnation Multi-hole frame fixing Solder tag terminations100% electrical and flash tested Tested in accordance with BS3535 and EN 60 742.
High quality safety and isolating transformers designed for ...
Description:
High quality safety and isolating transformers designed for use in control circuits and general applications Low loss noise laminations Dual standard primary winding 230 / 400Vac with +15V tap for input flexibility Dual secondaries are centre tapped. Earth terminal provided Varnish impregnated for overall protection against humidity and rusting Fully ...
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins100% electrical and flash tested Low inter-winding capacitance Low radiated noise Extra fixing ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.