Eaton Bussmann Series 225A British Standard Fuse, FM, 660V ac, 80 → 85mm

Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
Product Details

Eaton Bussmann Series Bolted Tag Fuse - Fast Acting (FF) HRC Power Fuse Range

Eaton Bussmann Series bolted tag fuse is essentially a fuse that is fitted with brackets, these brackets allow the fuse to be bolted onto a fuse holder. Predominantly this type of fuse is used within installations as a "weak link". They are designed to break when a fault occurs, such as an overcurrent or short circuit - they are a safety and damage protection measure. Cooper Bussman's fuses are commonly found within a multitude of industrial applications, electrical equipment and wiring systems.

Features & Benefits

• Compact dimensions
• Excellent current limiting features
• High-speed clearance of AC and DC faults
• Featured a melt Point Curve Class IEC 269-4
• Fuse links, specifically designed for the protection of applications
• Conforms to industry standards
• Low voltage fuse

Specifications
Attribute Value
Current Rating 225 A
Fuse Size FM
Voltage Rating 660 V ac
Fuse Standard BS 88, IEC 269-4
Fixing Centres 80 → 85mm
Tag Width 25.4mm
Fuse Speed FF
High Rupture Capacity Yes
Overall Length 113mm
Body Diameter 38mm
Body Height 50mm
Available to back order for despatch 30/10/2020
Price Each
£ 101.61
(exc. VAT)
£ 121.93
(inc. VAT)
Units
Per unit
1 - 9
£101.61
10 - 49
£80.46
50 - 99
£64.63
100 - 249
£54.07
250 +
£48.78
Related Products
Die geschraubte Sicherung der Eaton Bussmann-Serie ist im ...
Description:
Die geschraubte Sicherung der Eaton Bussmann-Serie ist im Wesentlichen eine Sicherung mit Halterungen, mit denen die Sicherung auf einen Sicherungshalter geschraubt werden kann. Diese Art von Sicherung wird hauptsächlich in Anlagen als "Schwachstelle" verwendet. Sie sind so konzipiert, dass sie bei Auftreten eines Fehlers wie Überstrom oder Kurzschluss brechen - ...
As the fuse allows for the starting surge ...
Description:
As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating. e.g. 20 M25 must not have a continuous load of greater than 20A. Breaking capacity 80kA ac 40k AdcRated up to 550Vac/ 250Vdc (Type A1) ...
Utility fuse-link, LV, 500 A, AC 415 V ...
Description:
Utility fuse-link, LV, 500 A, AC 415 V 88/J, 49 x 131 mm, gL/gG , 92mm fixing centres.
Fuse-link, LV, 32 A, AC 440 V 88/F1, ...
Description:
Fuse-link, LV, 32 A, AC 440 V 88/F1, 15 x 62 mm, gL/gG.