Technical Reference
Legislation and Compliance
RoHS Status: Not Applicable
Product Details
Eaton Auxiliary Contacts For Use With The PKZ 0 System
A flexible and modular system built for motors up to 4 kW/400 V, the PKZ 0 system offers efficiency whilst being economical whatever the motor started performance profile. Eaton's fail-safe auxiliary contacts offer several contact combinations and are front or right-hand side mountable depending on their design, no tools needed! Trip indication presents through a red short-circuit indicator on some components, allowing users to view a trip easily, other information is provided to the upstream programmable controller. Information provided includes "on/off" on the protective switch, "tripped" message for overload or short circuits, and "on/off" for the contact module.
Features and benefits:
Front mount and side-mounted contacts available
Easy connection to motor-protective circuit-breakers
Screw terminal connections
On/off switch and module information
Easy connection to motor-protective circuit-breakers
Screw terminal connections
On/off switch and module information
For use with PKZM01, PKZM0, PKZM4, PKZM0-T, PKM0, and PKE.
Applications:
Electric motor starters, control systems, control, power circuits and electrical signalling equipment.
How do Auxiliary Contacts work?
An Auxiliary Contact block, or aux contact, is an electromechanical device that is mounted typically to contactors. They are physically connected to the contactor, with simultaneous activation and deactivation applying to both the contact block and the contactor at the same time.
Auxiliary contacts can be installed onto contactors either by front mounting, or side mounting. This is usually clear in the shape and size of the product, but please check the compatibility of your devices. Aux Contacts are really useful devices to aid in keeping an eye on the contactor.
Auxiliary contacts can be installed onto contactors either by front mounting, or side mounting. This is usually clear in the shape and size of the product, but please check the compatibility of your devices. Aux Contacts are really useful devices to aid in keeping an eye on the contactor.
Eaton Front Mount 1NO/1NC Auxiliary Contact - NHI-B-11-PKZ0
• Can be retrofitted on the right side of motor protection circuit breakers
• Screw type connecting terminals
• Contact current rating of 2 A (dc) and 1 A (ac)
• Contact voltage rating of 250 V dc and 440 V ac
• Screw type connecting terminals
• Contact current rating of 2 A (dc) and 1 A (ac)
• Contact voltage rating of 250 V dc and 440 V ac
Note
Eaton formerly known as Moeller
Specifications
Attribute | Value |
---|---|
Number of Contacts | 2 |
Normal State Configuration | 1NC + 1NO |
Mounting Style | Front Mount |
Series | Eaton Moeller |
Contact Current Rating | 1 A ac, 2 A dc |
Terminal Type | Screw |
Pole and Throw Configuration | DP |
Contact Voltage Rating | 250 V dc, 440 V ac |
Minimum Operating Temperature | -25°C |
Maximum Operating Temperature | +55°C |
Operating Temperature Range | -25 → +55 °C |